IBM Support

PH00625: CPSM ASRA IN EYU0XSRR AFTER APPLYING PTF FOR PI91378

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • You have the CPSM PTF applied for APAR PI91378, and find that
    you receive SVC dumps for an ASRA in CPSM method XSRR. That
    method is the Resource Release Method Receiver. CPSM will write
    a EYUXL0905E message that includes a PSW address. In an SVC
    dump however, that puts it in IEAVBWGL, a console services
    module from MVS.
    .
    The BEAR address puts us in EYUTXEPC which is a location in
    XEPC that would be making a branch to do an MVS WTO.
    .
    Additional Symptom(s) Search Keyword(s): KIXREVGJT
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICSPlex SM V5R3M0 and V5R4M0 Users.     *
    ****************************************************************
    * PROBLEM DESCRIPTION: ASRA abend may occur in method EYU0XSRR *
    *                      when a MAS region is cancelled or       *
    *                      terminated via CEMT PERFORM SHUTDOWN    *
    *                      IMMEDIATE command, after applying the   *
    *                      following PTFs:                         *
    *                                                              *
    *                      - V5R3M0, APAR PI91378, PTF UI54190     *
    *                      - V5R4M0, APAR PI91378, PTF UI54189     *
    ****************************************************************
    * RECOMMENDATION: After applying the PTF that resolves APAR    *
    *                 PH00625, the CPSM ESSS (Environment Service  *
    *                 System Services) subsystem address space     *
    *                 (EYUXvrm, where for example, vrm=530 for     *
    *                 CPSM V5R3M0 etc.) must be terminated on      *
    *                 every MVS image where a CMAS has executed    *
    *                 since the last IPL.                          *
    *                                                              *
    *                 This can be accomplished in either of two    *
    *                 ways:                                        *
    *                                                              *
    *                   1 - Ensure that module EYU9Xvrm in the     *
    *                       linklist concatenation is replaced by  *
    *                       the updated version from SEYULINK.     *
    *                                                              *
    *                     - IPL the MVS Image.                     *
    *                                                              *
    *                 Or:                                          *
    *                                                              *
    *                   2 - Stop all CMASes, MASes (including WUI  *
    *                       servers) and CPSM batch API programs   *
    *                       on an MVS image.                       *
    *                                                              *
    *                     - Use EYU9XENF to check that no address  *
    *                       spaces are connected to the ESSS       *
    *                       subsystem.                             *
    *                                                              *
    *                     - Use the EYU9XEUT TERMINATE function to *
    *                       stop the ESSS.                         *
    *                                                              *
    *                     - Ensure that module EYU9Xvrm in the     *
    *                       linklist concatenation is replaced by  *
    *                       the updated version from SEYULINK.     *
    *                                                              *
    *                     - Refresh LLA to ensure the updated      *
    *                       versions of the linklist modules are   *
    *                       picked up.                             *
    *                                                              *
    *                 Restart any CMASes, MASes (including WUI     *
    *                 servers) and CPSM batch API programs which   *
    *                 execute on the MVS image, insuring that the  *
    *                 updated libraries are being picked up.  When *
    *                 the first CMAS is started the EYUXvrm        *
    *                 address space will be started automatically. *
    *                                                              *
    *                 For details on the EYU9XEUT utility, refer   *
    *                 to:                                          *
    *                                                              *
    *                 - CICS Transaction Server for z/OS           *
    *                   - Troubleshooting and support              *
    *                     - Troubleshooting CICSPlex SM            *
    *                       - Tools for problem determination      *
    *                         - Using the ESSS utility(EYU9XEUT)   *
    *                                                              *
    *                 For details on the EYU9XENF utility, refer   *
    *                 to:                                          *
    *                                                              *
    *                 - CICS Transaction Server for z/OS           *
    *                   - Troubleshooting and support              *
    *                     - Troubleshooting CICSPlex SM            *
    *                       - Tools for problem determination      *
    *                         - Using the ESSS utility(EYU9XEUT)   *
    *                           - Using the ESSS Information       *
    *                             Display Utility (EYU9XENF)       *
    *                                                              *
    *                 Note that each MVS image can be updated      *
    *                 separately, and systems on an MVS image that *
    *                 are using the new code can communicate with  *
    *                 systems on other MVS images that are not yet *
    *                 using the new code.                          *
    ****************************************************************
    When a CPSM CMAS or MAS, including a WUI server, is cancelled
    while the QR TCB is in CPSM PC routine code, an abend S0C4 may
    occur in WTO processing code issued from the PC routine FRR
    code.
    
    Note that this may result in the CICS region not shutting down
    for the cancel request.
    

Problem conclusion

  • UI54190 UI54189
    
    Module EYU2XERT has been updated to make sure WTO being executed
    in correct ASC mode.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH00625

  • Reported component name

    CICS TS Z/OS V5

  • Reported component ID

    5655Y0400

  • Reported release

    00M

  • Status

    CLOSED PER

  • PE

    YesPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-07-17

  • Closed date

    2018-08-31

  • Last modified date

    2018-09-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI58243 UI58244

Modules/Macros

  • EYU0UCLD EYU0XCLD EYU9X530 EYU9X540 EYU9XECS EYUTXEMS EYUTXEPC
    

Fix information

  • Fixed component name

    CICS TS Z/OS V5

  • Fixed component ID

    5655Y0400

Applicable component levels

  • R00M PSY UI58243

       UP18/09/01 P F808 {

  • R10M PSY UI58244

       UP18/09/01 P F808 {

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.3","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.3","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: