A fix is available
APAR status
Closed as program error.
Error description
Reviewing the HOLD data for some service applied, there was mention of some CPSM related changes: . UI65181 ++HOLD(UI65181) SYSTEM FMID(HCI7200) REASON(ACTION) DATE(19240) COMMENT( This PTF adds a new field, HEXNAME, to the TSQSHR resource table. This increases the size of TSQSHR resource table records by 16 bytes. After a CMAS has been updated to this PTF level, any CICSPlex SM API programs which fetch or map the TSQSHR structure may need to be recompiled to allow for this increase before reconnecting to that CMAS. The TSQSHR structure is mapped by copybooks EYUA0100, EYUC0100, EYUL0100, EYUP0100. ). . The text above is for the 5.5 HOLD data and PTF UI65179 gave the same text for CPSM 5.4 - there was an additional mention of needing to restart the ESSS at 5.4. When the 5.5 CMAS was recycled, the following message was issued and the CMAS was isolated from the plex: . EYUCP0022E Maintenance point for plexname on cmasid1 has a lower capability than cmasid2. CMAS cmasid2 will be isolated from the CICSplex. . A dump was also take for this CMAS out of CSLT for the LSRT transaction: EYUXZ0910I cmasid EYU0XZPT Dump,cmasid,cmasid,lpar,CMAS,LSRT,task#,TRAC,EYU0CSLT,date,time. . When the MP CMAS was later restarted it seemed to have connected and synchronized without issue, but the non-MP CMAS remained isolated from the plex. To resolve this isolation problem the non-MP CMAS would need to be restarted.
Local fix
n/a
Problem summary
**************************************************************** * USERS AFFECTED: All CPSM Users. * **************************************************************** * PROBLEM DESCRIPTION: The PTFs for APAR PH14288 were * * shipped with incomplete ++HOLD data. * **************************************************************** * RECOMMENDATION: After applying the PTF that solves PH14288, * * all regions (including CMAS, WUI and * * MAS) must be restarted to pick up the * * changes. Note that the restarts do not need * * to occur at the same time. However if * * systems are not restarted at the same time, * * the following rules apply: * * . * * - Maintenance Point (MP) CMASes must be * * restarted on the updated code before * * non-MP CMASes. * * . * * - If you have more than one MP CMAS and any * * of those MP CMASes are connected directly * * or indirectly, then those MP CMASes * * must be restarted at the same time. * * . * * - Before a MAS, regardless of whether it is * * running as a WUI server, is restarted * * with the updated code, the CMAS to which * * the MAS connects must be running with the * * updated code. * * . * * - This fix is being provided across the * * following releases of CICSPlex SM: * * . * * - CPSM V5R2M0 - APAR PH14288 / PH18399 * * - CPSM V5R3M0 - APAR PH14288 / PH18399 * * - CPSM V5R4M0 - APAR PH14288 / PH18399 * * - CPSM V5R5M0 - APAR PH14288 / PH18399 * * . * * Before a CMAS running with the PTF that * * resolves this APAR for its release * * connects directly or indirectly to a CMAS * * running a higher release of CPSM, the * * higher release CMAS must be restarted so * * that it is running with the appropriate * * PTF for its release. * **************************************************************** The PTFs for APAR PH14288 were shipped with incomplete HOLD data. Information describing the required action was included as a Comment in the PTF cover letter, rather than as a ++HOLD ACTION item. These PTFs must be replaced with new PTFs containing the additional ++HOLD ACTION information.
Problem conclusion
UI65178 UI65180 UI65179 UI65182 The affected PTFs have been superseded by new PTFs containing the required HOLD ACTION information.
Temporary fix
Comments
APAR Information
APAR number
PH18399
Reported component name
CICS TS Z/OS V5
Reported component ID
5655Y0400
Reported release
20M
Status
CLOSED PER
PE
YesPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-10-22
Closed date
2019-10-30
Last modified date
2019-11-30
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI66147 UI66148 UI66149 UI66150
Modules/Macros
CJF0NAG0 CJFTNAGF CJG0NAG0 CJGTNAGG CJH0NAG0 CJHTNAGH EYU0NAG0 EYUA0100 EYUC0100 EYUE0100 EYUL0100 EYUP0100 EYUT0100 EYUTNAGF EYUTNAGG EYUTNAGH EYUTNAGI EYUY0100
Fix information
Fixed component name
CICS TS Z/OS V5
Fixed component ID
5655Y0400
Applicable component levels
R00M PSY UI66149
UP19/10/31 P F910 {
R10M PSY UI66148
UP19/10/31 P F910 {
R20M PSY UI66150
UP19/10/31 P F910 {
R90M PSY UI66147
UP19/11/04 P F911 {
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.5","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.5","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
30 November 2019