Error description
When you start up your MAS region in optimized mode, and the RS server is not available at that time, message EYUWM008 is issued to indicate the failure. However, the message WM0508 failed to send out because of a mis- sing insert.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All CICSPlex SM V5R2M0 Users * **************************************************************** * PROBLEM DESCRIPTION: - CPSM fails to issue EYUWM0508 * * message during AOR activation * * processing because of a missing * * insert. * * * * - For the following messages, when * * they are issued from the MAS heart- * * beat processing, the length of * * CICSplex field is 16-bytes long * * string with extra blanks. However, * * the field should be 8-bytes long. * * * * - EYUWM0503 * * - EYUWM0504 * * - EYUWM0505 * * - EYUWM0506 * * - EYUWM0507 * * - EYUWM0508 * * * * - For message EYUWM0507 and EYUWM0508, * * you will see the open parenthesis * * for the optimization termination * * reason field is missing. * * * * - CPSM fails to issue message EYUWM- * * 0506 during RS failure processing * * because of an invalid insert type, * * and CICSplex field for message * * EYUWM0508, EYUWM0504 and EYUWM0507 * * is blank. * **************************************************************** * RECOMMENDATION: After applying the PTF that resolves this * * APAR, all CMASes and MASes must be recycled * * to pick up the new code. Note that regions * * do not need to be brought down and restarted * * at the same time. * **************************************************************** - When an CICS region joins the workload as an AOR, method WMAA (EYU0WMAA - WLM AOR Activation) is called for the AOR activation. EYUWM0508 is issued for optimization initializa- tion failure. However, CPSM fails to issue EYUWM0508 message because of a missing insert. - Method WNHD (EYU0WNHD - WLM MAS Heartbeat) is called during the MAS heartbeat processing. The following message are issued indicating different conditions for the MAS region: - EYUWM0503 - EYUWM0504 - EYUWM0505 - EYUWM0506 - EYUWM0507 - EYUWM0508 However, the CICSplex field is passed 16 bytes long variable. As a result, the messages in the log have extra blanks. - Message definitions for EYUWM0507 and EYUWM0508 do not have an open parenthesis for the optimization termination reason field. - Method WNRS (EYU0WNRS - WLM RS Domain Wrapper) is called for RS failure processing. The following messages are issued: - EYUWM0506 - EYUWM0508 - EYUWM0504 - EYUWM0507 However, WNRS fails to issue EYUWM0506 message, because the the specified insert type is invalid. For other messages, the CICSplex field is blank because it is not set correctly before it is used.
Problem conclusion
To resolve the problems, the following changes have been made: - Module EYU0WMAA(WMAA) has been updated to add CICSplex insert when calling XMSM to issue message EYUWM0508. - Module EYU0WNHD(WNHD) has been updated to pass 8-bytes long variable when calling XMSM to issue the following messages: - EYUWM0503 - EYUWM0504 - EYUWM0505 - EYUWM0506 - EYUWM0507 - EYUWM0508 - Message EYUWM0507 and EYUWM0508 have been updated to add the open parenthesis for the optimization termination reason field. - Module EYU0WNRS(WNRS) has been updated to: - Use correct insert type for EYUWM0506 message. - Inquire and set the variable of CICSplex field before it is used for message EYUWM0508, EYUWM0504 and EYUWM0507.
Temporary fix
********* * HIPER * ********* FIX AVAILABLE BY PTF ONLY
Comments
APAR Information
APAR number
PI20675
Reported component name
CICS TS Z/OS V5
Reported component ID
5655Y0400
Reported release
90M
Status
CLOSED PER
PE
NoPE
HIPER
YesHIPER
Special Attention
NoSpecatt
Submitted date
2014-06-24
Closed date
2014-08-27
Last modified date
2015-03-19
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI20918
Modules/Macros
CJA0WNHD CJA0WNRS CJB0WNHD CJB0WNRS CJC0WNHD CJC0WNRS CJD0WNHD CJD0WNRS CJE0WNHD CJE0WNRS EYU0WMAA EYU0WNHD EYU0WNRS EYUMCWMC EYUMCWME EYUMCWMK
GC34731000 |
Fix information
Fixed component name
CICS TS Z/OS V5
Fixed component ID
5655Y0400
Applicable component levels
R90M PSY UI20918
UP14/08/29 P F408 ½
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
19 March 2015