IBM Support

PI78994: DFHSR0606 ABEND (CODE 315/AKEB) HAS BEEN DETECTED, CICS OR CMAS IS TERMINATED.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • BATCHREP to small output file brings down CMAS region after
    system abend code 315. CICS is unable to recover from this
    abend code and terminates with DFHSR0606 message.
    I was running a batchrep report but the output to a DSN PDSE
    was so large that it ran out of space.
    This caused an AKEB abend that brought the entire CMAS region
    down.
    .
    Error messages received were:
    IEC032I E37-04,IGC0005E,CPSMCMAS,SYS00013,363B
    
    IEC911I 315-00,CPSMCMAS,SYS00013,0000000C,1C0B52D4
    +DFHSR0606 M04CLM01 Abend (code 315/AKEB) has been detected.
    .
    This APAR is raised to request that z/OS system abend code
    315 is added to the CICS SRT and allow CICS to recover from
    abend 315.
    

Local fix

  • https://www.ibm.com/support/knowledgecenter/SSGMCP_5.1.0/com.ibm
    .cics.ts.doc/eyua7/topics/eyua7a9.html
    'If a partitioned data set is used as the output data set, you
    must ensure that the data set has enough space to handle the
    output. A full partitioned data set without sufficient
    directory space may cause multiple abends resulting in the
    termination of the CMAS. To avoid multiple abends during CICS
    recovery, direct output to a sequential data set. If required,
    you can then copy the sequential data set output to a
    partitioned data set.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICS users.                              *
    ****************************************************************
    * PROBLEM DESCRIPTION: CICS terminates following a 315 abend.  *
    ****************************************************************
    A user was running a CPSM batchrep report but failed to make
    the output PDSE dataset large enough. It ran out of space
    resulting in abend code 315 during the processing of an SVC 21
    instruction. As CICS does not have system recovery code to
    handle 315 abend codes, and one was not coded in the SRT
    itself, the region terminated with an AKEB abend.
    KEYWORDS: CMAS abend315 315x abendakeb system svc21
    

Problem conclusion

  • DFHSRT has been changed to handle 315 abend codes and prevent
    the region from terminating if they occur.
      The following doc change will be made to the CICS
    Transaction Server for z/OS V5.1 Resource Definition Guide
    (SC34-2868-00), chapter 40, page 507, for DFHSRT TYPE=
    SYSTEM/USER:
      The table under Note 1, listing the abend codes which CICS
    intercepts and attempts recovery for, will be amended to
    include codes 16E and 315.
    .
      The following doc change will be made to the CICS
    Transaction Server for z/OS V5.2 Resource Definition Guide
    (SC34-7290-00), chapter 40, page 519, for DFHSRT TYPE=
    SYSTEM/USER:
      The table under Note 1, listing the abend codes which CICS
    intercepts and attempts recovery for, will be amended to
    include codes 16E and 315.
    .
      The following doc change will be made to the CICS
    Transaction Server for z/OS V5.3 Resource Definition Guide
    (SC34-7425-00), chapter 40, page 520, for DFHSRT TYPE=
    SYSTEM/USER:
      The table under Note 1, listing the abend codes which CICS
    intercepts and attempts recovery for, will be amended to
    include codes 16E and 315.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI78994

  • Reported component name

    CICS TS Z/OS V5

  • Reported component ID

    5655Y0400

  • Reported release

    800

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-03-29

  • Closed date

    2017-05-22

  • Last modified date

    2017-06-20

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI47411 UI47412 UI47413 PI83324

Modules/Macros

  • DFHSRT   DFHSRT1$
    

Publications Referenced
SC34286800SC34729000SC34742500  

Fix information

  • Fixed component name

    CICS TS Z/OS V5

  • Fixed component ID

    5655Y0400

Applicable component levels

  • R000 PSY UI47411

       UP17/05/24 P F705

  • R800 PSY UI47412

       UP17/05/24 P F705

  • R900 PSY UI47413

       UP17/05/24 P F705

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: