A fix is available
APAR status
Closed as program error.
Error description
On an IMMEDIATE shutdown of CICS, an 0C4 abend occurs followed by an abend C03. The 0C4 occurs in moduel IDA0200B at x'D26' trying to access the AMB via Reg5. This area has been freed which results in a C03 abend. This seems to have to do with when the FO TCB is detached by DFHKETCB when it takes longer than 10 seconds. In this case, closing the vsam files takes longer than 15 seconds.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All CICS users * **************************************************************** * PROBLEM DESCRIPTION: ABEND0C4 and ABENDC03 during an * * Immediate Shutdown. * **************************************************************** * RECOMMENDATION: * **************************************************************** During an Immediate Shutdown the FO (File Owning) TCB can be detached before all VSAM data sets have been closed. This can cause an ABEND0C4 in module IDA0200B at offset X'D26' followed by an ABENDC03. Also message IEC161I with codes 058(018)-061 may appear for VSAM data sets at CICS Startup if the FO TCB was abnormally detached at shutdown, and an automatic VERIFY will be done on these data sets. Additional Keywords: IEC999I MSGIEC999I IFG0TC0A IFG0TC0B MSGIEC161I SC03 S0C4 0C4 C03 OA09116 MSGDFHKE1798
Problem conclusion
DFHKETCB has been altered to give the FO TCB 60 seconds in which to terminate at immediate shutdown, and KCB_CANT_TERMINATE_FO will be set if the 60 seconds is exceeded. DFHKESIP will issue a new message DFHKE1798 if this flag is set. The CICS Transaction Server for z/OS CICS Messages and Codes Version 3 Release 1 manual, GC34-6442-00, will be updated to add the following new message for DFHKE1798 :- DFHKE1798 APPLID FO TCB FORCED TO TERMINATE. EXPLANATION: During an Immediate Shutdown the File Owning TCB was detached before VSAM was able to close all data sets normally. It is possible that the detaching of this TCB will cause abends during shutdown. At CICS restart VSAM may need to perform a VERIFY for any data set which was open for update when the Immediate Shutdown was performed, and this can cause a long delay. During initialization, CICS may not have access to the user's applid coded in the SIT. If CICS produces this message in these circumstances, it uses the default applid value DBDCCICS. SYSTEM ACTION: The immediate shutdown of CICS continues. USER RESPONSE: None. If this message occurs frequently, you may wish to issue a CEMT SET FILE ALL CLOSED before Immediate Shutdown. NOTE: This message cannot be changed with the message editing utility. DESTINATION: Console MODULE: DFHKESIP
Temporary fix
FIX AVAILABLE BY PTF ONLY
Comments
APAR Information
APAR number
PK06888
Reported component name
CICSTS 3.1 Z/OS
Reported component ID
5655M1500
Reported release
400
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2005-06-07
Closed date
2005-06-23
Last modified date
2006-09-18
APAR is sysrouted FROM one or more of the following:
PK03021
APAR is sysrouted TO one or more of the following:
UK04779
Modules/Macros
DFHKESIP DFHKETCB DFHMEKEC DFHMEKEE DFHMEKEK DFH06888 MFHMEKEE
GC34644200 |
Fix information
Fixed component name
CICSTS 3.1 Z/OS
Fixed component ID
5655M1500
Applicable component levels
R400 PSY UK04779
UP05/06/29 P F506
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1","Edition":"","Line of Business":{"code":"","label":""}}]