A fix is available
APAR status
Closed as program error.
Error description
When applying UK03947 (and after deleting the SMPLTS) the following messages will result, IEW2456E and IEW2470E.
Local fix
Do not delete SMPLTS
Problem summary
**************************************************************** * USERS AFFECTED: All. * **************************************************************** * PROBLEM DESCRIPTION: When applying PTF UK03947 message * * IEW2456E SYMBOL DFHRMUWH UNRESOLVED * * MEMBER COULD NOT BE INCLUDED FROM * * THE DESIGNATED CALL LIBRARY. * * can be issued. * **************************************************************** * RECOMMENDATION: * **************************************************************** When applying PTF UK03947 for Apar PK03330 message IEW2456E SYMBOL DFHRMUWH UNRESOLVED. MEMBER COULD NOT BE INCLUDED FROM THE DESIGNATED CALL LIBRARY can be issued. Message IEW2470E ORDERED SECTION DFHRMUWH NOT FOUND IN MODULE may also be issued. This is because DFHRMUWH was defined incorrectly causing the PTF to be built so that the code shipped for ++MOD DFHRMUWH contained the MODHEAD DFHRMUW3. Additional keywords: DFHSIP SMPSW#1 IPRRUMWH MSGIEW2456 MSGIEW2470 Additional Symptoms: Abend 0C4 reported in DFHSIP, occurring in DFHKERER trying to write kernel error information for an abend 0C1. The 0C1 is due to an unresolved address for DFHRMUWH from DFHRMUO at offset 3338. The problem occurs because UK03947 was applied and it did not resolve the DFHRMUWH address. You should have received an error when you tried to apply UK03947 like: IEW2456E SYMBOL DFHRMUWH UNRESOLVED. The dump shows that UK03947 is applied. If CICS was in Syncpoint processing at the time and program checked in DFHRMUO then program checked again, CICS will terminate. In one scenario, the customer canceled an AOR and the associated TOR came down with the 0C1 and 0C4. The unresolved reference for DFHRMUWH leads to R2=40404040 in DFHRMUO and a CDS (Compare Double Swap) program checks. The loader shows UK03947 is applied. The last 2 trace entries have a RET address into DFHRMSLW. Additional Keywords: KERNPOWN ABENDS0C4 ABEND0C4 ABENDS0C1 ABEND0C1
Problem conclusion
UK03947 The SPA definition SMPSW#1 for DFHRMUWH has been changed to Y ( Ship text ) and DFHRMUWH has been reshipped.
Temporary fix
FIX AVAILABLE BY PTF ONLY
Comments
APAR Information
APAR number
PK08173
Reported component name
CICSTS 3.1 Z/OS
Reported component ID
5655M1500
Reported release
400
Status
CLOSED PER
PE
YesPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2005-06-30
Closed date
2005-07-11
Last modified date
2005-09-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK05482 UK05486
Modules/Macros
DESRMUW3 DFHRMUWH
Fix information
Fixed component name
CICSTS 3.1 Z/OS
Fixed component ID
5655M1500
Applicable component levels
R400 PSY UK05482
UP05/08/02 P F508
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
02 September 2005