A fix is available
APAR status
Closed as program error.
Error description
The DFHMAINJ post installation job for CICS SFR highlights errros in DFHMASMD and DFHMAXCV. . In DFHMASMD - statement 52, continuation is in the wrong column causing the DEFINE QLOCAL to fail. For example if: - input to DFHMAINR was: - CICS.INITQ CICSXX.INITQ - substitution string was 2 characters longer & the continuation character is 2 spaces too far to the right. - note that re-running the DFHMASET job is not easy since the job does not delete datasets that it allocates and the DEFINE QLOCAL command says "NOREPLACE". . In DFHMAXCV - comments in statements 1017 through 110017 are in the wrong columns for assembler input, causing the DFHCNV assembly to fail.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of CICS SFR * **************************************************************** * PROBLEM DESCRIPTION: Two sample modules supplied in the CICS * * SFR samplib contain errors which cause * * post-install jobs to fail. * **************************************************************** * RECOMMENDATION: * **************************************************************** Samplib member DFHMASMD contains the option INITQ(cics.initq) in the middle of a Define Q Local, and as such also has a continuation character. DFHMAINR manipulates the information provided in the Define Q Local but fails to handle the substitution of the INITQ correctly and so moves its continuation character to the wrong column. This results in messages CSQN205I, CSQ9019E and CSQ9023E being produced. Samplib member DFHMAXCV is prefixed by comments which do not start in the correct column and this results in message IEB336I being issued when DFHMAXCV is included in DFHCNV. Additional keywords MSGCSQN205I CSQN205 N205I N205 MSGCSQ9019E CSQ9019 9019E 9019 MSGCSQ9023E CSQ9023E 9023E 9023 MSGIEB336I IEB336 336I 336 SCIZSAMP
Problem conclusion
DFHMASMD has been amended such that the parameter "INITQ(cics.initq)" is now the last statement in the DEFINE QLOCAL to which it belongs. As a result, it no longer contains a continuation character at the end of its line. DFHMAXCV has been changed such that all comment lines starting with an asterisk now begin in column 1, rather than column 6 as was previously the case.
Temporary fix
Comments
APAR Information
APAR number
PK25736
Reported component name
SERVICE FLOW FE
Reported component ID
5655M1502
Reported release
200
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2006-05-30
Closed date
2006-07-27
Last modified date
2006-08-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK16639
Modules/Macros
DFHMASMD DFHMAXCV
Fix information
Fixed component name
SERVICE FLOW FE
Fixed component ID
5655M1502
Applicable component levels
R200 PSY UK16639
UP06/07/29 P F607
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSC5SJS","label":"Service Flow Feature"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
01 August 2006