A fix is available
APAR status
Closed as program error.
Error description
When a START CHANNEL is shipped to a remote system over MRO, exception traces and AXGA abends occur in DFHAPCR IMPORT_ALL on the receiving system. The problem is that the overall length of the flattened channel in the TIOA is incorrect, and so DFHAPCR continues to loop looking fro additional data beyond the end of the TIOA. The reason is that on the sending side, the size of the container pool ( cpcb_pool_size) is incorrect -counting each container twice. This seems to be a consequence of the change made in APAR PK20794.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All CICS users. * **************************************************************** * PROBLEM DESCRIPTION: An abend AXGA occurs when an EXEC CICS * * START CHANNEL command is issued for a * * remote transaction. * **************************************************************** * RECOMMENDATION: * **************************************************************** When an EXEC CICS START TRANSID() CHANNEL() command is issued for a remote SYSID, a container pool is built to ship the channel data to the remote system. DFHPGCP incorrectly doubles the length of the container pool, and an incorrect length channel is shipped. This results in an abend AXGA on the remote system. Additional keywords: ABENDAXGA DFHAC2206 MSGDFHAC2206 APCR02
Problem conclusion
UK14435 DFHPGCP has been changed to build the container pool with the correct length.
Temporary fix
FIX AVAILABLE BY PTF ONLY
Comments
APAR Information
APAR number
PK28986
Reported component name
CICSTS 3.1 Z/OS
Reported component ID
5655M1500
Reported release
400
Status
CLOSED PER
PE
YesPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2006-08-01
Closed date
2006-10-12
Last modified date
2006-11-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK18678
Modules/Macros
DESPGCP DFHPGCP DFHPGCPA DFHPGCPI DFHPGCPM DFHPGCPT
Fix information
Fixed component name
CICSTS 3.1 Z/OS
Fixed component ID
5655M1500
Applicable component levels
R400 PSY UK18678
UP06/10/14 P F610
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
02 November 2006