PK30370: MSGDFHPI0001 AN ABEND (CODE 0C4/AKEA) HAS OCCURRED AT OFFSET X'5226' IN DFHPIPL WHEN <TERMINAL_HANDLER> IS NOT CODED.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • MSGDFHPI0001 An abend (code 0C4/AKEA) has occurred at offset
    X'5226' in DFHPIPL when <terminal_handler> is missing from the
    header file.
    Our customer was able to insert the <terminal_handler> statement
    in the file and did not error. Our customer believes a dump and
    outage is too drastic and a message would be more appropriate
    in this scenario.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICS users.                              *
    ****************************************************************
    * PROBLEM DESCRIPTION: Abend 0C4 in DFHPIPL at offset X'5226'  *
    *                      when installing a provider PIPELINE     *
    *                      if the xml file does not contain a      *
    *                      <terminal_handler> tag.                 *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    When a PIPELINE definition for a service provider is installed,
    the xml configuration file is parsed. The <terminal_handler> tag
    is a required tag for a provider pipeline, but if it is missing,
    DFHPIPL will continue scanning past the end of the data. This
    eventually results in an abend 0C4.
    
    Additional keywords: ABEND0C4 ABENDS0C4 S0C4 AKEA ABENDAKEA
    MSGDFHPI0720 DFHPI0001 PI0001
    

Problem conclusion

  • DFHPIPL has been changed to detect that the <terminal_handler>
    tag is missing, from an otherwise valid xml configuration file,
    and produce message DFHPI0720.
    

Temporary fix

  • FIX AVAILABLE BY PTF ONLY
    

Comments

  • ž**** PE06/11/22 FIX IN ERROR. SEE APAR PK35085  FOR DESCRIPTION
    

APAR Information

  • APAR number

    PK30370

  • Reported component name

    CICSTS 3.1 Z/OS

  • Reported component ID

    5655M1500

  • Reported release

    400

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2006-08-23

  • Closed date

    2006-09-20

  • Last modified date

    2007-04-24

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK18238

Modules/Macros

  •    DESPIPL  DFHPIPL
    

Fix information

  • Fixed component name

    CICSTS 3.1 Z/OS

  • Fixed component ID

    5655M1500

Applicable component levels

  • R400 PSY UK18238

       UP06/09/26 P F609

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1","Edition":"","Line of Business":{"code":"","label":""}}]