A fix is available
APAR status
Closed as program error.
Error description
MSGDFHPI0001 An abend (code 0C4/AKEA) has occurred at offset X'5226' in DFHPIPL when <terminal_handler> is missing from the header file. Our customer was able to insert the <terminal_handler> statement in the file and did not error. Our customer believes a dump and outage is too drastic and a message would be more appropriate in this scenario.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All CICS users. * **************************************************************** * PROBLEM DESCRIPTION: Abend 0C4 in DFHPIPL at offset X'5226' * * when installing a provider PIPELINE * * if the xml file does not contain a * * <terminal_handler> tag. * **************************************************************** * RECOMMENDATION: * **************************************************************** When a PIPELINE definition for a service provider is installed, the xml configuration file is parsed. The <terminal_handler> tag is a required tag for a provider pipeline, but if it is missing, DFHPIPL will continue scanning past the end of the data. This eventually results in an abend 0C4. Additional keywords: ABEND0C4 ABENDS0C4 S0C4 AKEA ABENDAKEA MSGDFHPI0720 DFHPI0001 PI0001
Problem conclusion
DFHPIPL has been changed to detect that the <terminal_handler> tag is missing, from an otherwise valid xml configuration file, and produce message DFHPI0720.
Temporary fix
FIX AVAILABLE BY PTF ONLY
Comments
**** PE06/11/22 FIX IN ERROR. SEE APAR PK35085 FOR DESCRIPTION
APAR Information
APAR number
PK30370
Reported component name
CICSTS 3.1 Z/OS
Reported component ID
5655M1500
Reported release
400
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2006-08-23
Closed date
2006-09-20
Last modified date
2007-04-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK18238
Modules/Macros
DESPIPL DFHPIPL
Fix information
Fixed component name
CICSTS 3.1 Z/OS
Fixed component ID
5655M1500
Applicable component levels
R400 PSY UK18238
UP06/09/26 P F609
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
24 April 2007