A fix is available
APAR status
Closed as program error.
Error description
Customer has very old existing workload. It appears two transaction definitions were, sometime in the past, altered to change the DESCRIPTION field of the definition. Afterwards, an Install of the workload would produce EYUWM0426 message indicating the two altered transactions failed to be installed due to already being installed via the same workload. However, a WLMATRAN view from the WUI does not show the two transactions in question.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All CICSPlex SM V3R2M0 Users * **************************************************************** * PROBLEM DESCRIPTION: When a WLMDEF is dynamically installed * * into an active workload, transactions * * associated with the WLMDEF's TRANGRP * * may not be added into the workload if * * the install results in a EYUWM0426I * * message to the EYULOG indicating that * * the WLMDEF is already isntalled: * * * * EYUWM0426I Definition (<wdefname>) * * already installed in * * Workload (<workloadname>) * * - parameter ignored. * * * * Subsequent attempts to re-install the * * definition will continue to receive the * * same EYUWM0426I message. If the * * transactions are removed from the * * TRANGRP and added to another TRANGRP * * associated with a different WLMDEF, * * attempts to install that WLMDEF will * * result in a different message * * EYUWM0426I to the EYULOG, this one * * indicating that the TRANSACTION(s) are * * already installed: * * * * EYUWM0426I Transaction (<tranid>) * * already installed in * * Workload (<workloadname>) * * - parameter ignored. * * * * The only way to get the transactions * * installed into the workload will be to * * terminate and restart the workload. * **************************************************************** * RECOMMENDATION: After applying the PTF that resolves this * * APAR, all CAMSes must be restarted. Note * * that the restarts do not need to occur at * * the same time. * **************************************************************** When a WLMDEF is dynamically installed into an active workload, method EYU0WMWI (WMWI) verifies if the WLMDEF is already installed in the workload, and if so, attempts to resolve any differences between the original version of the WLMDEF, and the current version. If the only difference is the description of the WLMDEF or the WLMDEF update time, WMWI incorrectly fails the install of the WLMDEF with EYULOG message EYUWM0426I indicating that the WLMDEF is already installed, but performs a partial install of the transactions associated with the WLMDEF's TRANGRP. Subsequent attempts to install the transactions, through the same WLMDEF/TRANGRP combination will continue to fail with the same EYUWM0426I message. Because of the partial install that occurs during the first install attempt, if the transactions are moved to a different WLMDEF/TRANGRP combination, the install of that WLMDEF will fail with the EYUWM0426I message indication that the transactions are already installed.
Problem conclusion
WMWI has been updated to not fail the re-install of a WLMDEF if the only difference between the new version and the previous version is the WLMDEF description or the last update time. Additionally, if WMWI does fail an install request because of a problem with the WLMDEF or the TRANGRP, it will no longer perform a partial install of the transactions associated with the WLMDEF/TRANGRP.
Temporary fix
FIX AVAILABLE BY PTF ONLY
Comments
APAR Information
APAR number
PK45182
Reported component name
CICSTS 3.X Z/OS
Reported component ID
5655M1500
Reported release
50M
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2007-05-15
Closed date
2007-07-24
Last modified date
2007-08-03
APAR is sysrouted FROM one or more of the following:
PK40387
APAR is sysrouted TO one or more of the following:
UK27367
Modules/Macros
EYU0WMWI
Fix information
Fixed component name
CICSTS 3.X Z/OS
Fixed component ID
5655M1500
Applicable component levels
R50M PSY UK27367
UP07/07/26 P F707
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
03 August 2007