IBM Support

PK47482: LMAS DOES NOT CONNECT TO LOCAL CMAS. EXCEPTION TRACE HAS AN ENTRY FROM XSRS WITH DEBUG:INSUFSTG

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • You have a CICS (LMAS) region that is connecting to the CMAS,
    but after you have successfully install your resources
    (EYUBN0099I), you see message EYUNL0901, normal shutdown entered
    on the LMAS job log.  There are not any error messages in the
    JESMSGLOG or the EYULOG of the CMAS.
    We found that EYU0XSRS is requesting a global lock for EYU0XELK
    and gets a response of XELK_QUEUE_NOT_AVAILABLE (X'14'). This
    causes XSRS to issue the trace entry with the debug text of
    INSUFSTG.
    At the time of the failure EYU9XEUT is executed requesting the
    dump of the locks:
    Total number of Resource Queues                131,072
    Number of Resource Queues in use               131,060  ( 99.9%)
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICSPlex SM V3R2M0 Users                 *
    ****************************************************************
    * PROBLEM DESCRIPTION:    You see Topology Connect and Join    *
    *                      failures after several hundred MASes    *
    *                      have already connected to a plex.  You  *
    *                      see message EYUTS0002E in the CMAS      *
    *                      joblog, and you may also see message    *
    *                      .                                       *
    *                           EYUNL0901I  LRT NORMAL termination *
    *                                initiated                     *
    *                      .                                       *
    *                      in the LMAS job log.  The AUXTRACE for  *
    *                      the the CMAS and any affected LMAS's    *
    *                      contains user exception records written *
    *                      by method XSRS (EYU0XSRS - Global Lock  *
    *                      Registration), with a Debug text of     *
    *                      INSUFSTG.  A dump of the global lock    *
    *                      manager via the EYU9XEUT program showed *
    *                      131,060 out of 131,072 global lock ele- *
    *                      ments were in use.                      *
    ****************************************************************
    * RECOMMENDATION: After applying the PTFs that resolve this    *
    *                 APAR, all CPSM Environment Services System   *
    *                 Services (ESSS) Address Spaces must be       *
    *                 restarted before any CMASes, MASes or CPSM   *
    *                 API programs are run which access the        *
    *                 updated code.  The ESSS may be restarted in  *
    *                 two ways :                                   *
    *                                                              *
    *                 1 - IPL the MVS Image.                       *
    *                                                              *
    *                 Or, if an IPL is not possible:               *
    *                                                              *
    *                 2 - Stop all CMASes and MASes on the MVS     *
    *                     image.                                   *
    *                   - Use EYU9XENF to check that no Address    *
    *                     Spaces are connected to the ESSS.        *
    *                   - Use the EYU9XEUT TERMINATE function to   *
    *                     stop the ESSS service address space.     *
    *                   - Refresh LLA to ensure the updated        *
    *                     version of EYU9X320 is picked up.        *
    *                   - Restart the CMASes and MASes, ensuring   *
    *                     that the updated libraries are being     *
    *                     picked up.                               *
    *                                                              *
    *                    For details on EYU9XENF and the EYU9XEUT  *
    *                 TERMINATE function refer to the manual "CICS *
    *                 Transaction Server for z/OS CICSPlex SM      *
    *                 Problem Determination Version 3 Release 2"   *
    *                 (GC34-6852-xx).                              *
    *                                                              *
    *                    Note that each MVS image can be updated   *
    *                 separately, and systems on an MVS image that *
    *                 are using the new code can communicate with  *
    *                 systems on other MVS images that are not yet *
    *                 using the new code.                          *
    ****************************************************************
       CPSM locking is implemented in the ESSS Subsystem;  a pool
    of 131,072 resource lock blocks is maintained in the private
    area of the EYUX320 address space on each LPAR.  If multiple
    CMASes managing the same plex reside on a single MVS image, the
    need to maintain resource topology cache lists for all MASes
    in the plex in each CMAS's TOP cache data space may cause the
    resource lock block pool to be exhausted.  This may result in
    failures including, but not limited to, failure to complete
    CMAS-to-CMAS connections when new CMASes become active, failure
    of Topology Connect or Join to complete, and failures in methods
    which create new queues or cache lists, because new global locks
    cannot be registered.
       This is more likely to occur when two CMASes running the same
    release of CPSM are started in the same MVS image.
    

Problem conclusion

  •    The global lock pool, which is allocated from the extended
    private area of the EYUX320 address space when the ESSS is
    initialized, was increased to 262,144 lock elements and 524,288
    Holder/Waiter elements.
    

Temporary fix

  • FIX AVAILABLE BY PTF ONLY
    

Comments

APAR Information

  • APAR number

    PK47482

  • Reported component name

    CICSTS V3 Z/OS

  • Reported component ID

    5655M1500

  • Reported release

    50M

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2007-06-21

  • Closed date

    2007-07-06

  • Last modified date

    2007-08-03

  • APAR is sysrouted FROM one or more of the following:

    PK47554

  • APAR is sysrouted TO one or more of the following:

    UK26831

Modules/Macros

  •    EYUTXEPC EYUUXEEQ EYU9X320
    

Fix information

  • Fixed component name

    CICSTS V3 Z/OS

  • Fixed component ID

    5655M1500

Applicable component levels

  • R50M PSY UK26831

       UP07/07/07 P F707

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: