A fix is available
APAR status
Closed as program error.
Error description
You are in a CICS VSE 1.1.1 environment, and you use CECI to inquire on a terminal. By mistake you enter a connection name instead of a terminal on the query. The results is a program check occurring in DFHEIQST(UQ76247) on a convert to binary instruction (CVB). The problem does not occur if CEMT inquire is issued a Ter(xxxx) NOT FOUND is returned. Additional Symptom(s) Search Keyword(s): ABEND_ASRA, DFHAP0001 AB/UAKEA RIDS/DFHEIQST ADRS/000018D4 KIXREVxxx
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All. * **************************************************************** * PROBLEM DESCRIPTION: Abend ASRA when issuing an INQUIRE * * TERMINAL using EXEC CICS or CECI. * **************************************************************** * RECOMMENDATION: * **************************************************************** When an INQUIRE TERMINAL is issued via EXEC CICS or CECI, an abend ASRA occurs due to an 0C7 occurring in DFHEIQST at offset '18D4'. The abend occurs because a connection id is specified instead of a terminal id. In DFHEIQST, the code continues thinking that a terminal id has been specified and eventually attempts a CVB (convert to binary) against what it believes is a packed decimal TASKID. Since the connection does not have a packed decimal at the appropriate offset, an 0C7 is issued. Additional Keywords. 0C7 ASRA abendASRA EIQST INQ abend0C7 TCTE_TRANNUM
Problem conclusion
DFHEIQST has been altered to ensure that if a connection id is detected then a TERMIDERR response is issued.
Temporary fix
FIX AVAILABLE BY PTF ONLY
Comments
APAR Information
APAR number
PK62686
Reported component name
CICSTS FOR VSE
Reported component ID
564805400
Reported release
B0P
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2008-03-13
Closed date
2008-05-16
Last modified date
2008-11-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK36537
Modules/Macros
DFHEIQST
Fix information
Fixed component name
CICSTS FOR VSE
Fixed component ID
564805400
Applicable component levels
RB0P PSY UK36537
UP08/05/20 P E420
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.1.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
10 November 2008