PK62802: ISSUING INQ SYS CICSTSLEVEL RETURNS BINARY ZEROES FOR THE DATA1 VALUE, WHEN ISSUING IT IN A PROGRAM

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • In a program (both ASM and COBOL) the command EXEC CICS INQUIRE
    SYSTEM CICSTSLEVEL(ws-area) incorrectly returns binary zeros,
    and gives RESP = 0 and RESP2 = 0.
    CEMT I SYS returns 010101, as it should.
    This failure only happens when it is used in a program.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All                                          *
    ****************************************************************
    * PROBLEM DESCRIPTION: EXEC CICS INQUIRE SYSTEM CICSTSLEVEL    *
    *                      returns binary zeros.                   *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    If CICSTSLEVEL is the only parameter on an EXEC CICS INQUIRE
    SYSTEM command, binary zeros are returned with a normal
    response. If other parameters are present, the correct
    version, release and modification level are returned.
    CEMT INQUIRE SYS and CECI INQUIRE SYSTEM also return the
    correct result.
    

Problem conclusion

  • DFHEIQSA has been modified so that an EXEC CICS INQUIRE SYSTEM
    CICSTSLEVEL command returns the correct version, release and
    modification level when CICSTSLEVEL is the only parameter.
    

Temporary fix

  • FIX AVAILABLE BY PTF ONLY
    

Comments

APAR Information

  • APAR number

    PK62802

  • Reported component name

    CICSTS FOR VSE

  • Reported component ID

    564805400

  • Reported release

    B0P

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2008-03-19

  • Closed date

    2008-06-20

  • Last modified date

    2008-11-10

  • APAR is sysrouted FROM one or more of the following:

    PQ40898

  • APAR is sysrouted TO one or more of the following:

    UK37472

Modules/Macros

  •    DFHEIQSA
    

Fix information

  • Fixed component name

    CICSTS FOR VSE

  • Fixed component ID

    564805400

Applicable component levels

  • RB0P PSY UK37472

       UP08/06/23 P E420

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.1.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]