IBM Support

PK64502: DFHCA5204 COMMAND NOT EXECUTED. RESPWAIT KEYWORD IS NOT VALID.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • You have a CMAS and WUI server at CICS release 3.2.  It is
    managing MAS's that are CICS 3.1.  You try to install a PIPELINE
    definition into the CICS 3.1 MAS, and receive the following
    error message:
    .
    DFHCA5204 E mm/dd/yyyy hh:mm:ss applid ???????? COIE Command not
    executed. 'RESPWAIT' keyword is not valid.
    .
    The problem is that BAS isn't checking the release of CICS where
    the definition is being installed to make sure that RESPWAIT is
    valid.  It was added as a new paramenter in CICS 3.2 and is not
    valid in a CICS 3.1 region.
    .
    Additional Symptom(s) Search Keyword(s): MSGDFHAC5204
    KIXDCFCIC650
    KIXREVrer
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICSPlex SM V3R2M0 Users                 *
    ****************************************************************
    * PROBLEM DESCRIPTION: A customer site has a CMAS and a WUI    *
    *                      server at CICS release 3.2.  It is      *
    *                      managing MAS's that are CICS 3.1.       *
    *                      Trying to install a PIPELINE definition *
    *                      using the CPSM WUI or a CPSM batch API  *
    *                      may receive one or both of the          *
    *                      following error messages on the joblog  *
    *                      of the MAS where the definition is to   *
    *                      be installed:                           *
    *                      .                                       *
    *                        DFHCA5204 E mm/dd/yyyy hh:mm:ss       *
    *                        applid ???????? COIE Command not      *
    *                        executed.  'RESPWAIT' keyword is not  *
    *                        valid.                                *
    *                      .                                       *
    *                        DFHCA5204 E mm/dd/yyyy hh:mm:ss       *
    *                        applid ???????? COIE Command not      *
    *                        executed. 'POLICYDIR' keyword is not  *
    *                        valid.                                *
    *                      .                                       *
    *                      Examination of the CPSM auxiliary trace *
    *                      data set from the CMAS may reveal the   *
    *                      following EXCPs:                        *
    *                      .                                       *
    *                      Method   PT-ID   Debug Text             *
    *                      ------   -----   ----------             *
    *                      BNCF       5     CREPLVFL               *
    ****************************************************************
    * RECOMMENDATION: After applying the PTF that resolves this    *
    *                 APAR, all CMASes and MASes must be           *
    *                 restarted.  Note that the restarts do not    *
    *                 need to occur at the same time.              *
    ****************************************************************
    RESPWAIT and POLICYDIR are new PIPEDEF Resource Table attributes
    that were added to CPSM V3R2.
    
    Note: POLICYDIR is a CPSM reserved attribute that is not valid
    in CICS. It can be set through a batch API program, but CICS
    will fail the install request with the DFHCA5402 message if it
    is set.
    
    BAS method BNCF (EYU0BNCF - BAS MAS Support Program - 15) is not
    checking the release of CICS where the definition is being
    installed to make sure that RESPWAIT is valid.
    

Problem conclusion

  • Changed EYU0BNCF to check the release of CICS when a pipeline
    definition is being installed to make sure that attribute
    RESPWAIT is valid.  Additionally, branched around the code that
    checks POLICYDIR since it is not a valid CICS field.
    

Temporary fix

  • FIX AVAILABLE BY PTF ONLY
    

Comments

APAR Information

  • APAR number

    PK64502

  • Reported component name

    CICSTS V3 Z/OS

  • Reported component ID

    5655M1500

  • Reported release

    50M

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2008-04-15

  • Closed date

    2008-04-30

  • Last modified date

    2008-05-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK36053

Modules/Macros

  •    EYU0BNCF
    

Fix information

  • Fixed component name

    CICSTS V3 Z/OS

  • Fixed component ID

    5655M1500

Applicable component levels

  • R50M PSY UK36053

       UP08/05/01 P F804

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
02 May 2008