Error description
You are running with CICS TS 3.2 on RSU0803, and receiving the following: . DFHSM0001 An abend (code 0C4/AKEA) has occurred at offset X'1B72' in module DFHS2PP. . The problem occurs because DFHS2PP is not being set up correctly on entry. It is not being switched to basespace mode like the other DFHS2xx modules. Additional Symptom(s) Search Keyword(s): KIXREVrjl
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All. * **************************************************************** * PROBLEM DESCRIPTION: Abend 0C4/AKEA has occurred at offset * * X'1B72' in module DFHS2PP. * **************************************************************** * RECOMMENDATION: * **************************************************************** In the customer's case, an EXECKey USER application was running in subspace mode when it issued an EXEC CICS SET SYSTEM MAXTASKS. This command resulted in the request to obtain more storage above the bar. Before z/OS V1.10 access to above the bar storage is not allowed whilst running in subspace mode.
Problem conclusion
DFHSMSR has been changed to switch any task issuing a MXT_CHANGE_NOTIFY call to basespace before accessing above the bar storage.
Temporary fix
FIX AVAILABLE BY PTF ONLY
Comments
**** PE08/12/15 FIX IN ERROR. SEE APAR PK77484 FOR DESCRIPTION
APAR Information
APAR number
PK74787
Reported component name
CICSTS V3 Z/OS
Reported component ID
5655M1500
Reported release
500
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2008-10-30
Closed date
2008-11-07
Last modified date
2009-01-14
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK41467
Modules/Macros
DESSMSR DFHSMSR
Fix information
Fixed component name
CICSTS V3 Z/OS
Fixed component ID
5655M1500
Applicable component levels
R500 PSY UK41467
UP08/11/18 P F811
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
14 January 2009