Error description

  • You will see the message +EYUWI0084E WLM Query Workload was
    unable to locate object (2), key (CICSAPPL), update ignored
    after a DISCARD of the WLMDEF is done.
    It looks like CPSM does not make any changes to update the
    WLMSDEF's scope and leave it be in some of our lists.
    These lists are what an exporting CMAS uses to send information
    to an importing CMAS. The importing CMAS builds its initial
    information about AORs by the current scopes of the WLMSPEC
    and installed  WLMDEFs.  Then it processes the information
    from the exporting CMAS, which as a result of a DISCARD may have
    an entry to an AOR that is no longer part of the current scopes.
    This then will trigger the message +EYUWI0084E.
    Additional Symptom(s) Search Keyword(s):
    KIXREVMV
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICSPlex SM V3R2M0 Users                 *
    ****************************************************************
    * PROBLEM DESCRIPTION: When an active WLMDEF is discarded from *
    *                      a CPSM WLM workload, if a target region *
    *                      (AOR) that is within the WLMDEF's SCOPE *
    *                      is not part of any other SCOPE          *
    *                      associated with the workload, it will   *
    *                      not be removed from the workload.  This *
    *                      may result in message EYUWI0084E being  *
    *                      issued by other CMASes when they        *
    *                      subsequently import the workload.       *
    *                                                              *
    *                      The text of the EYUWI0084E message will *
    *                      be similar to the following:            *
    *                                                              *
    *                        EYUWI0084E  WLM Query Workload was    *
    *                                    unable to locate object   *
    *                                    (2), key (<aorname>),     *
    *                                    update ignored.           *
    ****************************************************************
    * RECOMMENDATION: After applying the PTF that resolves this    *
    *                 APAR, all CMASes must be restarted.  Note    *
    *                 that the restarts do not need to occur at    *
    *                 the same time.                               *
    ****************************************************************
    When a WLMDEF is discarded, method EYU0WMDF (WMDF) is called in
    all CMASes that have the workload installed to process the
    discard request.  As part of its processing, WMDF should call
    method EYU0WMRA (WMRA) to process the target regions that are
    part of the WLMDEF's SCOPE.  If a target region that is part of
    the SCOPE is not associated with any other SCOPEs still active
    for the workload, WMRA will remove the target region from the
    workload.  A logic error in WMDF results in WMRA not being
    called.  As a result, the CMASes where WMDF runs will not remove
    target regions if appropriate.
    
    When a subsequent CMAS imports the workload from a CMAS where
    the target region was not removed properly, that CMAS will
    export to the importing CMAS an indication that the target
    region should be part of the workload.  Since the importing CMAS
    will have already built its target region list based upon the
    workload's active SCOPEs, it will not build an entry for the
    target region that should have been removed.  When it processes
    the indication from the exporting CMAS that the target region
    should be included, it will fail that request, issuing the
    EYUWI0084E error message.  The workload import will then
    continue.
    

Problem conclusion

  • WMDF has been updated to properly call WMRA when a WLMDEF is
    discarded.
    

Temporary fix

  • FIX AVAILABLE BY PTF ONLY
    

Comments

APAR Information

  • APAR number

    PK77912

  • Reported component name

    CICSTS V3 Z/OS

  • Reported component ID

    5655M1500

  • Reported release

    50M

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2008-12-31

  • Closed date

    2009-01-08

  • Last modified date

    2009-02-02

  • APAR is sysrouted FROM one or more of the following:

    PK78006

  • APAR is sysrouted TO one or more of the following:

    UK42920

Modules/Macros

  •    EYU0WMDF
    

Fix information

  • Fixed component name

    CICSTS V3 Z/OS

  • Fixed component ID

    5655M1500

Applicable component levels

  • R50M PSY UK42920

       UP09/01/10 P F901

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
02 February 2009