IBM Support

PK89501: RTASCOPE FORCE OPTION NOT AVAILABLE VIA WUI - CANNOT MAKE RTA ACTIVE WITH AN INHERIT

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When the scope of an RTA specification is a CICS system group,
    and you need to indicate how the CICS Systems comprising the
    CICS system group are to use the specification, there is no easy
    way of setting the RTASCOPE Update OPTION using the WUI.
    
    In the past, the EUI RTASCOPE view provided the ability to SET
    the Update OPTION column, when the CSYSDEF was part of a system
    group.  For example, use the SET command with Update OPTION
    FORCE:
    
     W1 =RTASCOPE==========EYUPLX01=EYUPLX01=DDMMMYYYY==HH:MM:SS=
    
     CMD RTA      Scope    Scope    Scope    Scope    Update
     --- SPEC---- NAME---- TYPE---- MODE---- LINK---- OPTION--
     SET RTASPEC  CICSGRP  SYSGROUP                   FORCE
    
    This would force all CICS systems in the CICS system group to
    inherit the new specification.
    
    
    Additional Keyword(s) and Symptom(s):
    KIXREVJXD
    

Local fix

  • Do the following:
         Administration views
         -> RTA system availability monitoring
            -> Specifications to system group links
    
    Select the RTA specification to System group association you
    want to update and click on the Remove button, to remove the
    link between the RTA specification definition and the system
    group.
    
    Click the Create button to select the FORCE option and click
    the Yes button.
    
    If you associate the RTA specification with a CICS system that
    is already active, the new specification will not be immediately
    active until you restart the system or do the following:
    
         CICSPlex SM Operations view
         -> MASs known to CICSplex
    
    From this MAS view, click on the MAS name:
     -if the 'Real time analysis status' field is set to No, change
      it to Yes and click 'Apply changes'.
     -if the 'Real time analysis status' field is set to Yes, change
      it to No, click 'Apply changes', set it to Yes and click
      'Apply changes' again.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICSPlex SM V3R2M0 Users                 *
    ****************************************************************
    * PROBLEM DESCRIPTION: The WUI does not provide an easy way to *
    *                      update the scope to specification       *
    *                      associations for RTA, Monitor, and WLM. *
    ****************************************************************
    * RECOMMENDATION: After applying the fix for this APAR, all    *
    *                 CMASes and MASes which act as a Web User     *
    *                 Interface (WUI) Server must be recycled to   *
    *                 pick up the changed code.  Note that the     *
    *                 restarts do not need to occur at the same    *
    *                 time.                                        *
    *                                                              *
    *                 Once a WUI server has been restarted, then   *
    *                 users of the CICSPlex SM supplied starter    *
    *                 set viewsets and menus must re-import the    *
    *                 updated starter set LNKSMSCG, LNKSMSCS,      *
    *                 LNKSRSCG, LNKSRSCS, LNKSWSCG, and LNKSWSCS   *
    *                 viewsets into the WUI server's repository in *
    *                 order to pick up the changes.                *
    *                                                              *
    *                 The viewsets can be re-imported either via   *
    *                 the AUTOIMPORTDSN and AUTOIMPORTMEM WUI      *
    *                 server initialization parameters or the      *
    *                 IMPORT (from a dataset) function of the COVC *
    *                 WUI transaction.                             *
    *                                                              *
    *                 If COVC is used to re-import the viewset,    *
    *                 ensure that the TYPE operand is set to ALL   *
    *                 or VIEWSET, and that the Import option is    *
    *                 set to OVERWRITE.                            *
    *                                                              *
    *                 Users who have copied the IBM supplied       *
    *                 starter set viewsets and menus to another    *
    *                 name will have to manually apply the changes *
    *                 made by the PTF that resolves this APAR to   *
    *                 those copies.                                *
    *                                                              *
    *                 For details on the AUTOIMPORTDSN and         *
    *                 AUTOIMPORTMEM WUI server initialization      *
    *                 parameters see 'Specify the Web User         *
    *                 Interface server initialization parameters'  *
    *                 in the "CICS Transaction Server for z/OS     *
    *                 Version 3 Release 2 Installation Guide"      *
    *                 (GC34-6812).                                 *
    *                                                              *
    *                 For details on the COVC IMPORT function see  *
    *                 'The CICSPlex SM Web User Interface          *
    *                 transaction (COVC)' in the "CICS Transaction *
    *                 Server for z/OS Version 3 Release 2 CICSPlex *
    *                 SM Web User Interface Guide" (SC34-6841).    *
    *                                                              *
    *                 The updated starter set viewset names that   *
    *                 need to be imported are:                     *
    *                                                              *
    *                   LNKSMSCG ViewSet : EYUxA4CH                *
    *                   LNKSMSCS ViewSet : EYUxA4CI                *
    *                   LNKSRSCG ViewSet : EYUxA4CJ                *
    *                   LNKSRSCS ViewSet : EYUxA4CK                *
    *                   LNKSWSCG ViewSet : EYUxA4CL                *
    *                   LNKSWSCS ViewSet : EYUxA4CM                *
    *                                                              *
    *                 Replace x with the required language version *
    *                 to be imported:                              *
    *                 E - English, K - Japanese, S - Chinese.      *
    *                                                              *
    *                 Insure that the import references the        *
    *                 SEYUVIEW dataset that was updated by the PTF *
    *                 that resolves this APAR.                     *
    ****************************************************************
    Provide WUI users the ability to update the information about
    the CICS systems or CICS sytem groups that are associated with
    an analysis, monitor, or workload specification. The current
    process requires the link to be removed and then recreated.
    The End User Interface (EUI) RTASCOPE, MONSCOPE, and WLMSCOPE
    views provided this ability in the past.
    

Problem conclusion

  • Added NameList processing to EYUZTAUS.
    
    Modified EYU0TAUS to retrieve the name of the SCOPE and the name
    of the OLD_SPECNAME from the Namelist.
    
    Modified EYU0VAPL (WUI Get Picklist) to support picklist
    processing for the new specification name parameter when it
    pertains to LNKSxSCx.
    
    Added a new action name (CHGSPEC) to the following resource
    tables:
    
    LNKSMSCG - Link MONSPEC to CICS system group
    LNKSMSCS - Link MONSPEC to CICS system
    LNKSRSCG - Link RTASPEC to CICS system group
    LNKSRSCS - Link RTASPEC to CICS system
    LNKSWSCG - Link WLMSPEC to CICS system group
    LNKSWSCS - Link WLMSPEC to CICS system
    
    The CHGSPEC action will be processed by method EYU0TAUS (TAUS -
    Update Spec Association Definition Method Receiver).
    
    Added a new task guide button and view name to support the new
    CHGSPEC action to the following views:
    
     EYUxA4CH - EYUSTARTLNKSMSCG
     EYUxA4CI - EYUSTARTLNKSMSCS
     EYUxA4CJ - EYUSTARTLNKSRSCG
     EYUxA4CK - EYUSTARTLNKSRSCS
     EYUxA4CL - EYUSTARTLNKSWSCG
     EYUxA4CM - EYUSTARTLNKSWSCS
    
    where x is the required language version:
    E - English, K - Japanese, S - Chinese.
    

Temporary fix

  • FIX AVAILABLE BY PTF ONLY
    

Comments

APAR Information

  • APAR number

    PK89501

  • Reported component name

    CICSTS V3 Z/OS

  • Reported component ID

    5655M1500

  • Reported release

    50M

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-06-22

  • Closed date

    2009-10-30

  • Last modified date

    2009-12-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    PK93753 UK51620

Modules/Macros

  •    DYU0VAPL EYUA5633 EYUA5634 EYUA5635 EYUA5636
    EYUA5637 EYUA5638 EYUCTAUS EYUC5633 EYUC5634 EYUC5635 EYUC5636
    EYUC5637 EYUC5638 EYUEA4CH EYUEA4CI EYUEA4CJ EYUEA4CK EYUEA4CL
    EYUEA4CM EYUE5633 EYUE5634 EYUE5635 EYUE5636 EYUE5637 EYUE5638
    EYUKA4CH EYUKA4CI EYUKA4CJ EYUKA4CK EYUKA4CL EYUKA4CM EYUK5633
    EYUK5634 EYUK5635 EYUK5636 EYUK5637 EYUK5638 EYUL5633 EYUL5634
    EYUL5635 EYUL5636 EYUL5637 EYUL5638 EYUP5633 EYUP5634 EYUP5635
    EYUP5636 EYUP5637 EYUP5638 EYUQTAUS EYURTAUS EYUR5633 EYUR5634
    EYUR5635 EYUR5636 EYUR5637 EYUR5638 EYUSA4CH EYUSA4CI EYUSA4CJ
    EYUSA4CK EYUSA4CL EYUSA4CM EYUS5633 EYUS5634 EYUS5635 EYUS5636
    EYUS5637 EYUS5638 EYUTRTOP EYUT5633 EYUT5634 EYUT5635 EYUT5636
    EYUT5637 EYUT5638 EYUYTAUS EYUY5633 EYUY5634 EYUY5635 EYUY5636
    EYUY5637 EYUY5638 EYUZTAUS EYU0TAUS EYU0VAPL EYU9TSPU EYU9TSP3
    EYU9TSP4 EYU9TSP5 LNKSMSCG LNKSMSCS LNKSRSCG LNKSRSCS LNKSWSCG
    LNKSWSCS
    

Publications Referenced
SC34684202SC34684502SC34684602  

Fix information

  • Fixed component name

    CICSTS V3 Z/OS

  • Fixed component ID

    5655M1500

Applicable component levels

  • R50M PSY UK51620

       UP09/11/03 P F911

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
02 December 2009