PK90697: DFHKE1800 WITHOUT ANY OTHER MESSAGES EXPLAINING WHY CICS ABENDED

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Your CICS region abended with abendu1800 .  There is no
    message that explains why CICS abended.  The messages that you
    do get are these:
    .
    You get several BPXP018I messages like this:
    BPXP018I THREAD 2420381000000000, IN PROCESS 84215338, ENDED
    WITHOUT BEING UNDUBBED WITH COMPLETION CODE 0033E000, AND REASON
    CODE 00000000.
    .
    And these messages:
    .
    AXMSC0041I Connection to server DFHNC.DFHNC001 has been closed.
    EYUXE0003I CICS01   End of Task entered for CICSPlex SM 320
    +DFHDU0303I CICS01 Transaction Dump Data set DFHDMPA closed.
    +DFHKE1800 CICS01   ABNORMAL TERMINATION OF CICS IS COMPLETE.
    IEF450I CICS01   CICS01   CICS01   - ABEND=S000 U1800
      REASON=00000000
    .
    There is no dump unless you had previously set a SLIP like
    the following:
    .
    SLIP SET,COMP=U1800,J=kixjob*,A=SVCD,SDATA=(ALLNUC,PSA,SQA,CSA,L
    SQA,RGN,LPA,TRT,SUMDUMP),END
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICS Users.                              *
    ****************************************************************
    * PROBLEM DESCRIPTION: The CICS region terminates with         *
    *                      an abendU1800 and MSGDFHKE1800          *
    *                      following an application abend0CA.      *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    A transaction running on an L8 TCB suffers an abend 0CA.  While
    this abend is being processed, the runaway interval is reached
    and CICS attempts to abend the task.  DFHKETIX abends the TCB
    with an abend999 and DFHKESTX is called to process the abend and
    issue an abendAICA.  However, DFHKESTX is already handling the
    abend0CA and this results in the CICS region being terminated
    with an abend U1800 and message DFHKE1800 being issued.
    
    Additional keywords: KE1800 abend1800 abendS0CA S0CA AICA
                         ABEND_999 999
    

Problem conclusion

  • DFHKETIX has been changed to not issue the abend 999 if flag
    KTCB_KESTX_IN_PROGRESS is on, indicating that DFHKESTX is
    already handling an abend.
    
    The CICS Transaction Server for z/OS Version 3 Release 1 CICS
    Supplementary Data Areas manual, GC34-6905-01, will be updated
    as follows:
    
    The length of KTCB_STIMER_AUTOMATIC in the KTCB Table Entry
    section of the KECB Kernel Control Blocks will increase by 8
    bytes to 344 bytes and the offsets of the fields following
    KTCB_STIMER_AUTOMATIC will also increase by 8 bytes as follows:
    
    Offset  Type       Len  Name (Dim)              Description
       Hex
    
     (BB8)  CHARACTER  344  KTCB_STIMER_AUTOMATIC   Automatic for
                                                    Stimer exit
    
     (D10)  CHARACTER   56  KTCB_ETXR_ AUTOMATIC    Automatic for
                                                    ETXRer exit
    
     (D48)  CHARACTER  704  KTCB_TCB_ AUTOMATIC     Automatic for
                                                    TCB code
    
    (1008)  CHARACTER    0 KTCB_AUTOMATIC_ END      End of automatic
                                                    areas
    
    (1008) CHARACTER     0 *                        Round to
                                                    double-word
    

Temporary fix

  •             *********
                * HIPER *
                *********
    FIX AVAILABLE BY PTF ONLY
    

Comments

APAR Information

  • APAR number

    PK90697

  • Reported component name

    CICSTS V3 Z/OS

  • Reported component ID

    5655M1500

  • Reported release

    400

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-07-07

  • Closed date

    2009-10-28

  • Last modified date

    2009-12-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    PK96825 UK51537 UK51538

Modules/Macros

  •    DFHKECB  DFHKEEDA DFHKEKIL DFHKERKE DFHKERPC
    DFHKERRI DFHKERRQ DFHKERRU DFHKESFM DFHKESGM DFHKESTX DFHKETIX
    DFHKETXR
    

Publications Referenced
GC34690501    

Fix information

  • Fixed component name

    CICSTS V3 Z/OS

  • Fixed component ID

    5655M1500

Applicable component levels

  • R400 PSY UK51537

       UP09/11/03 P F911

  • R500 PSY UK51538

       UP09/11/03 P F911

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
02 December 2009