Error description

  • The following message is issued repeatedly in the CMAS during
    startup:
    .
      EYUTS0063E applid Topology encountered an error processing
      a change to a CICS system group.
    .
    The stack for the abending task is: XLOP, TIST, TSLA, TSEC, XZPT
    and the trace shows an exception entry with debug test RecurGrp
    trace point ID 6.  The exception occurs on function EXTPSGC.
    This error occurs as CMASes are starting up and receiving
    updates to the DREP that occurred while they were down.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICSPlex SM V4R1M0 Users                 *
    ****************************************************************
    * PROBLEM DESCRIPTION: A CMAS which is a non-maintenance point *
    *                      CMAS for at least one CICSplex may      *
    *                      receive error message EYUTS0063E during *
    *                      startup when processing data repository *
    *                      updates from the maintenance point      *
    *                      CMAS.  The text of this message will be *
    *                      as follows:                             *
    *                                                              *
    *                        EYUTS0063E  Topology encountered an   *
    *                                    error processing a change *
    *                                    to a CICS system group.   *
    *                                                              *
    *                      This may be followed by message         *
    *                      EYUXZ0910I indicating that a dump was   *
    *                      taken.  The dump title displayed by the *
    *                      message will be similar to the          *
    *                      following:                              *
    *                                                              *
    *                        EYU0XZPT Dump,<cmasjobn>,<cmasname>,  *
    *                        <lpar>,CMAS,TIST,<tasknum>,           *
    *                        TRAC,EYU0TSEC,<date>,<time>           *
    ****************************************************************
    * RECOMMENDATION: After applying the PTF that resolves this    *
    *                 APAR, all CMASes must be restarted.  Note    *
    *                 that the restarts do not need to occur at    *
    *                 the same time.                               *
    ****************************************************************
    When a CMAS initializes, method EYU0TIML (TIML) is called to
    perform initialization for the Topology component.  As part of
    this processing, TIML calls method EYU0TIPC (TIPC) to read all
    Topology records for each CICSplex from the data repository, and
    create data structures for them.
    
    If records are added after initialization, then after the record
    is written to the data repository, method EYU0XDCR (XDCR) will
    generate an event to the Topology long running task TIST, which
    will then cause the appropriate data structures to be built for
    the record.
    
    If a CMAS is the maintenance point for a CICSplex, then it is
    not possible for records to be added to the data repository for
    the CICSplex until the CMAS completes initialization.  However,
    if a CMAS is a non-maintenance point CMAS, then it could receive
    updates for the data repository from the maintenance point CMAS
    while it is performing Topology initialization.  When this
    occurs, it is possible for TIST to attempt to build data
    structures for records that have already been processed by TIPC,
    which can result in the errors described above.
    

Problem conclusion

  • A non-maintenance point CMAS receives data repository updates
    from the maintenance point CMAS through method EYU0XDRS (XDRS).
    On entry, XDRS acquires a lock exclusively to serialize
    processing of all XDRS executions.  Method TIML has been updated
    to acquire this lock exclusively prior to calling TIPC, and to
    free if after TIPC completes processing.  This will ensure that
    records processed by TIPC are not also processed by TIST.
    

Temporary fix

  • FIX AVAILABLE BY PTF ONLY
    

Comments

APAR Information

  • APAR number

    PK91190

  • Reported component name

    CICS TS Z/OS V4

  • Reported component ID

    5655S9700

  • Reported release

    60M

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-07-13

  • Closed date

    2009-07-24

  • Last modified date

    2009-08-03

  • APAR is sysrouted FROM one or more of the following:

    PK82035

  • APAR is sysrouted TO one or more of the following:

    UK48629

Modules/Macros

  • EYUTXLPD EYU0TIML EYU0XDIN
    

Fix information

  • Fixed component name

    CICS TS Z/OS V4

  • Fixed component ID

    5655S9700

Applicable component levels

  • R60M PSY UK48629

       UP09/07/28 P F907

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.1","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
03 August 2009