PK93423: EXCEPTION TRACE POINT 'TR 0101' FOR OVERLENGTH-ENTRY ISSUED BY DFHTRPT DUE TO DATA2 LENGTH BEING TOO LONG FOR TRACE POINT FC9B

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • DFHZATT is calling trace program to issue a FC9B trace point id.
    DATA2 (TIOA), passed on the call, has a length of x'206C' (8300
    decimal). DFHTRPT checks to see if the length is larger than the
    maximum allowed (compares to field TRBLOCK_DATALIM (defined as
    x'FE8' or decimal 4072)). DFHTRPT determines the TIOA length
    (TIOATDL) is too large and issues an exception trace entry:
    TR 0101 TRPT *EXC* - OVERLENGTH-ENTRY : CALLING DOMAIN WAS AP :
               PARAMETER LIST WAS FUNCTION(TRACE_PUT) POINT_ID(FC9B)
               DATA1 17202448 , 00000004) DATA2(18AF100C , 0000206C)
    .
    DFHZATT, label ZATT_TRACE_TIOA should police TIOATDL and, if too
    large, issue extended trace entries to allow tracing of the
    entire TIOA.
    .
    Additional keywords:  KIXREVSCB
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICS users.                              *
    ****************************************************************
    * PROBLEM DESCRIPTION: Exception trace entry TR 0101 is        *
    *                      issued by DFHTRPT because DFHZATT       *
    *                      has passed x'206C' as the length        *
    *                      of DATA2 for trace entry FC9B.          *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Exception trace entry:
    TR 0101 TRPT *EXC* - OVERLENGTH-ENTRY : CALLING DOMAIN WAS AP :
    PARAMETER LIST WAS FUNCTION(TRACE_PUT) POINT_ID(FC9B) DATA1
    (17202448 , 00000004) DATA2(18AF100C , 0000206C)
    is issued by DFHTRPT because DFHZATT has passed the value of the
    terminal data length field, TIOATDL, (x'206C) as DATA2 for
    trace entry FC9B. This exceeds the maximum length allowed
    for a trace entry of 4072 bytes.
    Additional keywords: SC346828 SC34-6828 SC34682802
    

Problem conclusion

  • DFHZATT has been changed so that only the first 4000 bytes of
    data from the TIOA will be passed to DFHTRPT as DATA2 for trace
    entry FC9B.
    The AP FC9B trace entry in the CICS Transaction Server for z/OS
    Trace Entries V3.2 manual, SC34-6828-02, will be changed so
    that the data 2 item will now read:
    'Up to 4000 bytes of data from the TIOA'.
    

Temporary fix

  • FIX AVAILABLE BY PTF ONLY
    

Comments

APAR Information

  • APAR number

    PK93423

  • Reported component name

    CICSTS V3 Z/OS

  • Reported component ID

    5655M1500

  • Reported release

    500

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-08-07

  • Closed date

    2009-10-30

  • Last modified date

    2009-12-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    PK99415 UK51596

Modules/Macros

  •    DFHZATT
    

Publications Referenced
SC34682802    

Fix information

  • Fixed component name

    CICSTS V3 Z/OS

  • Fixed component ID

    5655M1500

Applicable component levels

  • R500 PSY UK51596

       UP09/11/06 P F911

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
02 December 2009