IBM Support

PM10955: ABEND0C4 IN EYU9XSEC DURING CMAS SHUTDOWN.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • During the normal shutdown of 3.1 CMAS and 0c4 occurs as seen
    in the message log :
    +DFHKE1799 APPLID   TERMINATION OF CICS IS COMPLETE
    EYUXS1101I Interval Timing termination has started
    EYUXS1026E Security Interface has intercepted
    abnormal termination S0C4
    EYUXS1027I Security Interface recovery has started
     IEA794I SVC DUMP HAS CAPTURED:  153
    DUMP TITLE=CICSPlex SM External Security Abend
    EYUXS1027I Security Interface recovery has started
    EYUXS1027I Security Interface recovery has started
    EYUXS1030S Security Interface Abend limit reached.
    .
    The 0C4 is repeated until the abend limit is reached as above.
    The 0C4 occurs in EYU9XSEC UK19858 +x'1E2' as R12 address
    is not available:
    PSW: 070C2000 AFC7B1D2  Instruction length:06 Interrupt code:011
    .
    Failing instruction text: D0544780 30F0D203 C07C3C28
    Translation exception address: 7F7AA000
    R12 is 7F7AA3D0 and should point to a valid XECB but the
    page of storage 7F7AA000 has been freemained along with the
    XECB leading to the 0c4.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICSPlex SM V4R1M0 Users                 *
    ****************************************************************
    * PROBLEM DESCRIPTION: One or more S0C4 abends may occur in    *
    *                      module EYU9XSEC at offset X'1E2' during *
    *                      CMAS termination.  If the abend occurs, *
    *                      it will repeat until the abend limit is *
    *                      reached.                                *
    *                                                              *
    *                      Messages similar to the following will  *
    *                      be issued at the time of abend:         *
    *                                                              *
    *                        DFHKE1799  TERMINATION OF CICS IS     *
    *                                   COMPLETE.                  *
    *                        EYUXS1101I Interval Timing            *
    *                                   termination has started    *
    *                        EYUXS1026E Security Interface has     *
    *                                   intercepted abnormal       *
    *                                   termination S0C4           *
    *                        EYUXS1027I Security Interface         *
    *                                   recovery has started       *
    *                        IEA794I SVC DUMP HAS CAPTURED:        *
    *                          DUMPID=<nnn> REQUESTED BY JOB       *
    *                                 (<jobname>)                  *
    *                          DUMP TITLE=CICSPlex SM External     *
    *                                     Security Abend           *
    *                        EYUXS1028I Security Interface         *
    *                                   recovery complete          *
    *                                                              *
    *                      Messages EYUXS1026E through EYUXS1028I  *
    *                      will be repeated for each S0C4 that     *
    *                      occurs until the abend limit is reached *
    *                      and the following messages are issued:  *
    *                                                              *
    *                        EYUXS1013I Interval Timing detached   *
    *                                   the external security      *
    *                                   manager interface          *
    *                        EYUXS1102I Interval Timing            *
    *                                   termination complete       *
    ****************************************************************
    * RECOMMENDATION: After applying the PTF that resolves this    *
    *                 APAR, all CMASes must be restarted.  Note    *
    *                 that the restarts do not need to occur at    *
    *                 the same time.                               *
    ****************************************************************
    During CMAS shutdown, module EYU9XSEC is POSTed for termination
    after the ESSS terminate process has been completed.  As part of
    termination processing, EYU9XSEC will clear the address of the
    security token in the ESSS Connection Block (XECB).  However
    since the XECB is freed as part of the previously performed ESSS
    terminate process, an S0C4 may occur when EYU9XSEC attempts to
    update it.
    
    If a S0C4 occurs, EYU9XSEC's ESTAE routine will get control,
    during which it will produce diagnostic information and then
    pass control to a retry routine.  EYU9XSEC's retry routine will
    return control to EYU9XSEC's main line logic, which will
    determine that it has been POSTed for termination, which will
    cause it to attempt to update the XECB again, resulting in
    another S0C4 abend.  This will continue until the abend limit is
    reached.
    

Problem conclusion

  • EYU9XSEC has been updated as follows:
    
    -  the XECB address is now always loaded from its maintained
       pointer when needed.  If the XECB has been freed, then the
       maintained pointer will be null and EYU9XSEC will bypass
       updating the XECB.
    
    -  if an abend occurs during termination processing, the ESTAE
       retry routine will branch to exit processing instead of the
       normal processing routine.
    

Temporary fix

  • FIX AVAILABLE BY PTF ONLY
    

Comments

APAR Information

  • APAR number

    PM10955

  • Reported component name

    CICS TS Z/OS V4

  • Reported component ID

    5655S9700

  • Reported release

    60M

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-03-29

  • Closed date

    2010-05-09

  • Last modified date

    2010-06-03

  • APAR is sysrouted FROM one or more of the following:

    PM10918

  • APAR is sysrouted TO one or more of the following:

    UK56763

Modules/Macros

  • EYU9XSEC
    

Fix information

  • Fixed component name

    CICS TS Z/OS V4

  • Fixed component ID

    5655S9700

Applicable component levels

  • R60M PSY UK56763

       UP10/05/11 P F005

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.1","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
03 June 2010