IBM Support

PM19338: PE58177 MISSING HOLD DATA MAY LEAD TO EYUCP0031E AND CMAS CONNEC TION FAILURE.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • PE58177-F006 Hold Action information is missing from UK58177.
    If you install PTF UK58177 to your CPSM 3.2 CMAS without
    installing the required CPSM 4.1 PTF UK58389, the CMASs fail
    to connect with messages:
    .
    EYUXD0031E CMAS32 Capability mismatch (LOW) for table
    2639/MASQRYER (Service=UK58177) Local=9/1 : Remote=0/0.
    EYUCP0017E CMAS32 Capability of CMAS CMAS410 is not valid for
                               this CMAS to connect.
    EYUCP0018E CMAS32 Resource type mismatch 1 with CMAS CMASE10 is
    ACTION.
    

Local fix

  • Apply co-requisite CPSM 4.1 PTF UK58389 and restart the CPSM
    4.1 CMAS before restarting CPSM 3.2 CMAS.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICSPlex SM V3R2M0 Users                 *
    ****************************************************************
    * PROBLEM DESCRIPTION:    If you bring up your CMAS executing  *
    *                      from libraries with PTF UK58177 applied *
    *                      without installing the required PTF for *
    *                      CPSM V4.1 (UK58389) the CMASes fail to  *
    *                      connect with messages:                  *
    *                      .                                       *
    *                         EYUXD0031E  Capability mismatch      *
    *                              (LOW) for table 2639/MASQRYER   *
    *                              (Service=UK58177) Local=9/1 :   *
    *                              Remote=0/0.                     *
    *                         EYUCP0017E  Capability of CMAS       *
    *                               cmasname  is not valid for     *
    *                              this CMAS to connect.           *
    ****************************************************************
    * RECOMMENDATION: If a CMAS executing from a library to which  *
    *                 the PTF resolving this APAR is applied con-  *
    *                 nects, directly or indirectly, to a CMAS     *
    *                 executing CICSPlex SM for CICS Transaction   *
    *                 Server V4.1, the PTF which resolves the fol- *
    *                 lowing APAR must be applied to all CMASes    *
    *                 executing CICSPlex SM for CICS Transaction   *
    *                 Server V4.1.                                 *
    *                                                              *
    *                   CTS 4.1 - CICSPlex SM 4.1.0 - APAR PK98569 *
    *                                                              *
    *                 CMASes do not have to be restarted at the    *
    *                 same time. However if CMASes are not         *
    *                 restarted at the same time, the following    *
    *                 rules apply:                                 *
    *                                                              *
    *                 - Maintenance Point (MP) CMASes (including   *
    *                   CMASes executing V4.1 of CICSPlex SM) must *
    *                   be restarted with the updated code before  *
    *                   non-MP CMASes.                             *
    *                                                              *
    *                 - If you have more than one MP CMAS and any  *
    *                   of your MP CMASes are connected directly   *
    *                   or indirectly, then those MP CMASes must   *
    *                   be restarted at the same time.             *
    *                                                              *
    *                 - CMASes executing V4.1 of CICSPlex SM which *
    *                   are connected directly or indirectly to    *
    *                   CMASes executing V3.2 of CPSM must be re-  *
    *                   started with the new code before CMASes    *
    *                   which execute V3.2 of CPSM.                *
    ****************************************************************
       PTF UK58177 does not contain an ACTION HOLD documenting the
    requirement that CMASes executing CICSPlex SM V4.1 must be run-
    ning from libraries with PTF UK58398 applied, before starting
    any CMASes executing CICSPlex SM V3.2 from libraries containing
    PTF UK58177.
    

Problem conclusion

  • The appropriate ACTION HOLD has been added.
    

Temporary fix

  •             *********
                * HIPER *
                *********
    FIX AVAILABLE BY PTF ONLY
    

Comments

  • ž**** PE10/11/29 FIX IN ERROR. SEE APAR PM27632  FOR DESCRIPTION
    

APAR Information

  • APAR number

    PM19338

  • Reported component name

    CICSTS V3 Z/OS

  • Reported component ID

    5655M1500

  • Reported release

    50M

  • Status

    CLOSED PER

  • PE

    YesPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-07-27

  • Closed date

    2010-08-04

  • Last modified date

    2010-12-09

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK59430

Modules/Macros

  •    DYU0MOXT DYU0VAFT DYU0VAGM DYU0VAGT DYU0VAGW
    DYU0VAST DYU0VASU DYU0VBRP DYU0VHDT DYU0VHLK DYU0VHPL DYU0VHTT
    DYU0VHVD DYU0VIFM DYU0VISE DYU0VISI DYU0VISP DYU0VISZ DYU0VMPR
    DYU9VKEC EYUA2639 EYUBVAPI EYUBVISS EYUBVIST EYUBXDEN EYUBXDRD
    EYUCXXRS EYUC2639 EYUEVGAR EYUE2639 EYUKVGAR EYUK2639 EYUL2639
    EYUP2639 EYUQACCK EYUQXXRC EYURVGAR EYURXDEQ EYUR2639 EYUSVGAR
    EYUS2639 EYUTACMD EYUTAEYU EYUTBNRC EYUTMOMI EYUTMOSD EYUTRDIR
    EYUTVOSX EYUTVTHE EYUTVTHK EYUTVTHS EYUT2639 EYUUACMD EYUUAGBL
    EYUUXXFI EYUUXXRS EYUUXXTC EYUY2639 EYU0ABAA EYU0ABAF EYU0ABAJ
    EYU0ABA4 EYU0ABA7 EYU0ABA9 EYU0ABM0 EYU0CRCK EYU0CTEX EYU0DXRC
    EYU0MOXT EYU0TICT EYU0TSRA EYU0VAFT EYU0VAGM EYU0VAGT EYU0VAGW
    EYU0VAST EYU0VASU EYU0VBRB EYU0VBRF EYU0VBRS EYU0VHDA EYU0VHDB
    EYU0VHDF EYU0VHDH EYU0VHDI EYU0VHDK EYU0VHDT EYU0VHLB EYU0VHLF
    EYU0VHPL EYU0VHTD EYU0VHTH EYU0VHTM EYU0VHTT EYU0VHVB EYU0VHVC
    EYU0VHVD EYU0VHVS EYU0VHVT EYU0VIFM EYU0VISE EYU0VISI EYU0VISP
    EYU0VISZ EYU0VKED EYU0VMPD EYU0XDER EYU0XDH3 EYU0XDH4 EYU0XDH7
    EYU0XDNR EYU0XDP1 EYU0XDP2 EYU0XDP4 EYU0XDP5 EYU0XDP6 EYU0XDQA
    EYU0XDQB EYU0XDQR EYU0XDQ2 EYU0XDW1 EYU0XDW2 EYU0XDW3 EYU0XDW8
    EYU0XDW9 EYU0XDY1 EYU0XDY2 EYU0XDY3 EYU0XDY4 EYU0XDY5 EYU0XDY7
    EYU0XLSD EYU0XL80 EYU0XQGQ EYU0XXRC EYU7VISS EYU7VIST EYU9XDF1
    EYU9XMAL JCI650MJ MASQRYER
    

Fix information

  • Fixed component name

    CICSTS V3 Z/OS

  • Fixed component ID

    5655M1500

Applicable component levels

  • R50M PSY UK59430

       UP10/08/06 P F008 ®

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: