IBM Support

PM22313: CPSM BAS IPCONN INSTALL FAILS WITH INVREQ, "NO VALUE WAS SPECIFIED FOR 'QUEUELIMIT'."

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • If an IPCONN definition is created in BAS, with a Queue Limit
    value specified that has less than 4 digits, the installation of
    that IPCONN definition will fail with the following messages:
    .
    In the WUI browser, you see the following messages
    .
    EYUVC1231E  'Install' (INSTALL) request failed. Request complete
                for 1 records. (Tableerror, Dataerror)
    EYUVC1272I  Action (INSTALL) failed. Nothing installed (31).
                       was specified for 'QUEUELIMIT'.
    .
    Additional Symptoms:
    KIXREVSVR
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICSPlex SM V3R2M0 Users                 *
    ****************************************************************
    * PROBLEM DESCRIPTION: A BAS-defined IPCONN definition install *
    *                      may fail if the QUEUELIMIT attribute    *
    *                      value specified has less than 4 digits. *
    *                      If the QUEUELIMIT attribute value       *
    *                      specified contains 4 digits the install *
    *                      may succeed, but the QUEUELIMIT value   *
    *                      will be incorrect because the last 3    *
    *                      digits will be truncated.               *
    *                                                              *
    *                      If the install fails a message similar  *
    *                      to the following will be issued by CICS *
    *                      to the MSGUSR file:                     *
    *                                                              *
    *                       DFHCA5205 E ???????? COIE Command not  *
    *                                   executed. No value was     *
    *                                   specified for 'QUEUELIMIT' *
    *                                                              *
    *                      - WUI users will receive messages:      *
    *                                                              *
    *                       EYUVC1231E  'Install' (INSTALL)        *
    *                                   request failed. Request    *
    *                                   complete for 1 records.    *
    *                                   (Tableerror, Dataerror)    *
    *                                                              *
    *                       EYUVC1272I  Action (INSTALL) failed.   *
    *                                   Nothing installed (31).    *
    *                                                              *
    *                      Examination of the CPSM auxiliary trace *
    *                      data set from the CMAS may reveal the   *
    *                      following EXCP:                         *
    *                                                              *
    *                      Method   PT-ID   Debug Text             *
    *                      ------   -----   ----------             *
    *                      BNCG       5     CREIPCFL               *
    ****************************************************************
    * RECOMMENDATION: After applying the fix for this APAR, all    *
    *                 MASes must be recycled to pick up the        *
    *                 changed code.  Note that the restarts do not *
    *                 need to occur at the same time.              *
    ****************************************************************
    CPSM uses the EXEC CICS CREATE command to install BAS resource
    definitions. In method BNCG (EYU0BNCG - CPSM BAS MAS support
    program) the move for the build of the CREATE command is
    truncating the QUEUELIMIT attribute value. The value is obtained
    from IPC_QLIMIT in EYUBBNCD (CPSM MAS Resource Create Attribute
    Skeletons) where it is incorrectly defined as 5 characters in
    length.
    

Problem conclusion

  • Changed the length of IPC_QLIMIT to 8 characters in EYUBBNCD.
    
    Rebuilt EYU0BNCG to pick up the new length of IPC_QLIMIT.
    

Temporary fix

  • FIX AVAILABLE BY PTF ONLY
    

Comments

APAR Information

  • APAR number

    PM22313

  • Reported component name

    CICSTS V3 Z/OS

  • Reported component ID

    5655M1500

  • Reported release

    50M

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-09-10

  • Closed date

    2010-10-11

  • Last modified date

    2010-11-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK61219

Modules/Macros

  •    EYUBBNCD EYU0BNCG
    

Fix information

  • Fixed component name

    CICSTS V3 Z/OS

  • Fixed component ID

    5655M1500

Applicable component levels

  • R50M PSY UK61219

       UP10/10/12 P F010

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: