A fix is available
APAR status
Closed as program error.
Error description
PE60399-F009 . After applying PTF UK60399 for APARs PM15214 and PM15583 for SYSPARM capability, the CICSPlex SM API copybook source for member XMLTRANS in the SEYUMAC, SEYUCOB, SEYUC370, and SEYUPL1 libraries for Assembler, Cobol, C, and PL1 contain the alias for the SYSPARM table. The XMLTRANS alias EYUA0197, EYUL0197, EYUC0197, and EYUP0197 for Assembler, Cobol, C, and PL1 is mapping SYSPARM. XLMTRANS alias should be picking up the EYUA0196, EYUL0196, EYUC0196, and EYUP0196 alias. . Additional Symptom(s) Search Keyword(s) CPSM API copy copybook c/370 kixrevwjb
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All CICSPlex SM V4R1M0 Users * **************************************************************** * PROBLEM DESCRIPTION: After applying PTF UK60399 for * * APARs PM15214 and PM15583, providing * * SYSPARM capability, the CICSPlex SM API * * copybook alias XMLTRANS in the SEYUMAC * * (Assembler), SEYUCOB (COBOL), SEYUC370 * * (C), and SEYUPL1 (PL/I) libraries * * points to the copy members for the * * SYSPARM table. The XMLTRANS alias * * should address copy members EYUA0196 * * for Assembler, EYUL0196 for COBOL, * * EYUC0196 for C, and EYUP0196 for PL/I. * * New copy members EYUA0197, EYUL0197, * * EYUC0197, and EYUP0197 should be ad- * * dressed by the SYSPARM alias. * **************************************************************** * RECOMMENDATION: After applying the PTF that resolves this * * APAR, all CMASes, MASes and WUI servers must * * be restarted. The restarts need not be per- * * formed at the same time, however if systems * * are not restarted at the same time the fol- * * lowing rules apply: * * * * - Maintenance Point (MP) CMASes must be re- * * started with the updated code before non- * * MP CMASes, MASes, and WUI Servers. * * * * - If you have more than one MP CMAS and any * * of those MP CMASes are connected directly * * or indirectly, then those MP CMASes must * * be restarted at the same time. * * * * - Before a MAS or WUI server runs with the * * updated code, the CMAS to which the MAS or * * WUI server connects must be restarted with * * the updated code. * * * * After applying the PTF that resolves this * * APAR all CICSPlex SM API programs written in * * Assembler, COBOL, C, or PL/I which reference * * XMLTRANS or SYSPARM resource tables must be * * recompiled using the corrected copy members. * **************************************************************** A configuration error in the SMP/E MCS prototypes for copy members EYUA0197, EYUC0197, EYUL0197, and EYUP0197 generated incorrect alias parameters in the ++MAC and ++SAMP MCS state- ments for these members. This resulted in the wrong aliases being created in the SEYUMAC, SEYUCOB, SEYUC370, and SEYUPL1 copy libraries when PTF UK60399 was applied.
Problem conclusion
The SMP/E MCS prototype file was corrected and a PTF was generated for this APAR, with correct alias parameters for the XMLTRANS copy members EYUA0196, EYUC0196, EYUL0196, and EYUP0196, and for the SYSPARM copy members EYUA0197, EYUC0197, EYUL0197, and EYUP0197.
Temporary fix
FIX AVAILABLE BY PTF ONLY
Comments
APAR Information
APAR number
PM26580
Reported component name
CICS TS Z/OS V4
Reported component ID
5655S9700
Reported release
60M
Status
CLOSED PER
PE
YesPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-11-11
Closed date
2010-11-16
Last modified date
2010-12-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK62230
Modules/Macros
DESWUPFM DESWUSCH DFHWUPFM DFHWUSCH DFHWUTBL EYU#NQGR EYUA0196 EYUA0197 EYUBCRTB EYUCCRSQ EYUCNQGR EYUCXXRS EYUC0196 EYUC0197 EYUE0196 EYUE0197 EYUK0197 EYUL0196 EYUL0197 EYUNNQGR EYUP0196 EYUP0197 EYUQNAGR EYUQNEP1 EYUQNQGR EYUQNQRA EYUQNQRB EYUQNQRC EYUQNQRD EYUQNQRE EYUQNQRG EYUQXXRC EYUQ0197 EYURNEP1 EYURNQGR EYURNQGW EYURNQRA EYURNQRB EYURNQRC EYURNQRD EYURNQRE EYURNQRG EYUR0196 EYUR0197 EYUS0197 EYUTCRTB EYUTMOMI EYUTMOSD EYUTNAGA EYUTNAGB EYUTNAGC EYUTRDIR EYUTRMAS EYUTVOSX EYUTVTGE EYUTVTGK EYUTVTGS EYUT0196 EYUT0197 EYUUCRSQ EYUUNAEQ EYUUXXFI EYUUXXRS EYUUXXTC EYUYNEP1 EYUYNQGR EYUYNQRA EYUYNQRB EYUYNQRC EYUYNQRD EYUYNQRE EYUYNQRG EYUY0196 EYUY0197 EYUZNEP1 EYUZNQGR EYUZNQRA EYUZNQRB EYUZNQRC EYUZNQRD EYUZNQRE EYUZNQRG EYU0CRCK EYU0DXRC EYU0NEP1 EYU0NHCT EYU0NPGR EYU0NQGF EYU0NQGR EYU0NQGT EYU0NQHT EYU0NQK1 EYU0NQK3 EYU0NQK6 EYU0NQK7 EYU0NQK8 EYU0NQK9 EYU0NQPG EYU0NQRA EYU0NQRB EYU0NQRC EYU0NQRD EYU0NQRE EYU0NQRG EYU0NQSN EYU0NQTK EYU0NSDC EYU0NSGR EYU9NAPU EYU9NAP3 EYU9NAP4 EYU9NAP6 EYU9NARU EYU9NAR3 EYU9NAR4 EYU9NAR6 EYU9XMAL JCI660MJ R66KERN SYSPARM XMLTRANS
Fix information
Fixed component name
CICS TS Z/OS V4
Fixed component ID
5655S9700
Applicable component levels
R60M PSY UK62230
UP10/11/23 P F011
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.1","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date: