IBM Support

PM31891: EYUXU0218I ISSUED WHEN USING BATCHREP TO REMOVE AND CREATE A CSGLCGCG.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When using BATCHREP to REMOVE a CSGLCGCG from a CSYSGRP and then
    add to another via a CREATE it fails with message:
    .
    EYUXU0218I CMASQAMP Batch CREATE request complete - Status
    (BAS_INCONSISTENT_SET) - Associated fields GROUP
    EYUXU0226E CMASQAMP A previous error has caused incomplete
    processing
    .
    23829 BMRB XCLL XDBM BAS EXCP       1 InConSet EUI
    09:39:51.23230 09:39:51.23230  1/26/11
    
    23829 XDBR XDBM XDBM DAT EXCP      14 MALERROR EUI
    09:39:52.22736 09:39:52.22736  1/26/11
    .
    The failing BATCHREP commands were :
    REMOVE CSGLCGCG  GROUP(GRP1)
                     TOGROUP(GRP12345)
     CREATE CSGLCGCG  GROUP(GRP1)
                      TOGROUP(GRP6789A)
    .
    

Local fix

  • Run the each command in separate BATCHREP jobs.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICSPlex SM V3R2M0 Users                 *
    ****************************************************************
    * PROBLEM DESCRIPTION:    You use BATCHREP to REMOVE a         *
    *                      CSGLCGCG (Group-in-Group) or CSGLCGCS   *
    *                      (System-in-Group) linkage from one      *
    *                      CSYSGRP and then CREATE a link between  *
    *                      the system or group and a different     *
    *                      CSYSGRP.  The CREATE command in your    *
    *                      BATCHREP stream fails with message:     *
    *                      .                                       *
    *                         EYUXU0218I  Batch CREATE request     *
    *                           complete -                         *
    *                           Status(BAS_INCONSISTENT_SET) -     *
    *                           Associated fields GROUP            *
    *                      .                                       *
    *                      Following BATCHREP commands are not     *
    *                      executed, and message:                  *
    *                      .                                       *
    *                         EYUXU0226E CMASQAMP A previous       *
    *                           error has caused incomplete        *
    *                           processing                         *
    *                      .                                       *
    *                      is issued at the end of the stream.     *
    ****************************************************************
    * RECOMMENDATION: After applying the PTF that resolves this    *
    *                 APAR, all CMASes must be recycled to pick    *
    *                 up the new code.  Note that the restarts     *
    *                 do not need to be done at the same time.     *
    ****************************************************************
       When a CICS group (CSYSGRP) or CICS system (CSYSDEF) is
    linked to a CSYSGRP, module EYU0TAAC (TAAC - Add System Group
    Link Definition) is called to add the new CSGLCGCG or CSGLCGCS
    record to the data repository.  TAAC calls module EYU0BMWU
    (BMWU - BAS Update CICS System Group) to check the configuration
    for consistency.
       After a Topology update completes, the BAS Management long-
    running task is notified of the change asynchronously, so that
    the resource install matrix can be updated.  If BMWU is called
    by TAAC before a previous update of the BAS matrix completes,
    a status of BAS_INCONSISTENT_SET or BAS_INCONSISTENT_SCOPES
    might be returned to TAAC.
    

Problem conclusion

  •    Module EYU0TAAC was modified to retry the call to BMWU up
    to five times with a one second delay between tries, if the
    status returned by BMWU is not OK, to allow time for an in-
    flight update notification to be completed.  This will be done
    if TAAC is called on behalf of a BATCH process (BATCHREP stream
    or batch API program).
    

Temporary fix

  • FIX AVAILABLE BY PTF ONLY
    

Comments

APAR Information

  • APAR number

    PM31891

  • Reported component name

    CICSTS V3 Z/OS

  • Reported component ID

    5655M1500

  • Reported release

    50M

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-02-04

  • Closed date

    2011-04-20

  • Last modified date

    2011-05-02

  • APAR is sysrouted FROM one or more of the following:

    PM31856

  • APAR is sysrouted TO one or more of the following:

    UK66846

Modules/Macros

  •    DYU0XDBX EYURXLMF EYU0TAAC EYU0XDBM EYU0XDBX
    EYU0XLSI
    

Fix information

  • Fixed component name

    CICSTS V3 Z/OS

  • Fixed component ID

    5655M1500

Applicable component levels

  • R50M PSY UK66846

       UP11/04/22 P F104

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: