PM38552: DFHSM0002 SEVERE ERROR (CODE X'0C05') IN MODULE DFHSMMG INVALID_STORAGE_CLASS

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Customer is receiving the following message,
    DFHSM0002 A severe error (code X'0C05') has
               occurred in module DFHSMMG
    
    The trace shows the following exception,
    SM 0C05 SMMG  *EXC* - Invalid_storage_class
                          - FUNCTION(GETMAIN)
                          GET_LENGTH(xxxx) SUSPEND(YES)
                          INITIAL_IMAGE(00)
    The stacks shows the following:
     DFHKETA
     DFHDSKE
     DFHXMTA
     DFHPGPG
     INITIAL_LINK
     DFHAPLI1
     LE370_INTERFACE
     INVOKE_FOR_RECURSION
     DFHSMMG
     GETMAIN
     HANDLE_INVALID
     SEVERE_ERROR
     DFHMEME
     SEND
     CONTINUE_SEND
     TAKE_A_DUMP_FOR_CALLER
     DFHDUDU
     SYSTEM_DUMP
     TAKE_SYSTEM_DUMP
    It appears that we are in DFHSMMG HCI660 at offset 2BE where
    we are checking Subpool value. SP_VALUE/r13+x'119'contains
    an invalid value causes this invalid_storage_class.
    The problem is due to your application executing an invalid
    command(i.e. EXEC CICS ISSUE SEND) while running under a
    non-terminal task.This APAR would simply detect such an
    invalid state and return an error back to your application,
    and you will have to correct your application.
    Additional Symptom(s) Search Keyword(s):
    KIXREVSWM MSGDFHSM0002
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All                                          *
    ****************************************************************
    * PROBLEM DESCRIPTION: DFHSM0002 SEVERE ERROR (CODE X'0C05')   *
    *                      when EXEC CICS ISSUE SEND is issued by  *
    *                      non-terminal task.                      *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    A non-terminal task issues EXEC CICS ISSUE SEND. This command is
    designed to be used by terminal transactions and a TCTTE is
    expected to be addressed by EISTCTTE.
    DFHEDI calls DFHEIP routine EICCSC30 to getmain a TIOA. As
    EISTCTTE is nulls, DFHEIP bypasses code which sets the
    storage class for the getmain to TERMINAL.
    This results in DFHSM0002 SEVERE ERROR (CODE X'0C05') when the
    getmain is issued. A getmain for TIOA storage can never succeed
    when the current task is non-terminal.
    The test of a non-terminal task should have been made by DFHEDI
    before it called DFHEIP.
    

Problem conclusion

  • DFHEDI has been changed so that when command EXEC CICS ISSUE
    SEND is made by a non-terminal task, an ABEND ADIS will be
    issued.
    
    The CICS Transaction Server for z/OS Version 4 Release 1
    CICS Messages and Codes ( GC34703501 ) will be changed.
    In chapter 3 (Transaction abend codes ) the following new
    abend will be inserted after the entry for abend code ADIR :-
    
    ADIS
    
    EXPLANATION:  EXEC CICS ISSUE SEND request has been issued
    from a task that has a non-terminal principal facility.
    
    SYSTEM ACTION:  A CICS transaction dump is provided to
    assist in problem determination.
    
    USER RESPONSE:  Use a terminal or device that is properly
    supported.
    
    MODULE:  DFHEDI
    

Temporary fix

  • FIX AVAILABLE BY PTF ONLY
    

Comments

APAR Information

  • APAR number

    PM38552

  • Reported component name

    CICS TS Z/OS V4

  • Reported component ID

    5655S9700

  • Reported release

    600

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-05-05

  • Closed date

    2011-05-24

  • Last modified date

    2011-09-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK68105 PM46911

Modules/Macros

  •    CHAPT023 DFHEDI   DFH38552
    

Publications Referenced
GC34703501    

Fix information

  • Fixed component name

    CICS TS Z/OS V4

  • Fixed component ID

    5655S9700

Applicable component levels

  • R600 PSY UK68105

       UP11/05/31 P F105

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.1","Edition":"","Line of Business":{"code":"","label":""}}]