PM48114: XLNX ABENDAICA OFFS X'21E' XQPQFAIL DEBUG POINTID 14

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • ERROR DESCRIPTION:
    Your CMAS issues the following messages and produces and
    SVCDUMP.
    
    EYUXL0900I   Starting Environment Recovery
    EYUXL0905E applid  AICA IN XQPQ, OFFSET 0000021E PSW=078D5000
    B11E5746
    EYUXL0905E INTC=0002 ILC=2 TXCP=00000000 SCODE=S???? TRAN=XLNX
    TASK=0053998
    EYUXL0905E Methods=XQPQ,XLNX,XLOP
    EYUXL0906I Registers at ABEND
    EYUXL0907I GPR0-GPR3  00000000  31D9DD80  00FDB388  311E5568
    EYUXL0907I GPR4-GPR7  000A9000  000A9028  045E9000  01FF002A
    EYUXL0907I GPR8-GPRB  000C0000  311E5528  308DA460  308295F0
    EYUXL0907I GPRC-GPRF  31D9D978  31D9DBD8  B11E5706  30BADCC8
    EYUXL0907I ARR0-ARR3  00000000  00000000  00000000  00000000
    EYUXL0907I ARR4-ARR7  01FF002A  01FF002A  01FF002A  00000000
    EYUXL0907I ARR8-ARRB  00000000  00000000  00000000  00000000
    EYUXL0907I ARRC-ARRF  00000000  00000000  00000000  00000000
    EYUXL0908I Storage At ABEND
    EYUXL0909I -20  31D8D707  40284028  D6034034  40344780
    EYUXL0909I -10  31D89A66  40305860  4034D503  601435FC
    EYUXL0909I +00  478031F2  58706014  58606018  B24E0067
    EYUXL0909I +10  47F031D8  51506000  5850603C  D503C030
    
    The internal CMAS trace table contains 10 exceptions with debug
    text XQPQFAIL with point id 14.  The AICA abend can occur if
    the kernel notify task has no locally connected MASes and has
    no need to broadcast the events.  If no plex broadcast is
    necessary, the XLNX task should suspend to avoid a possible
    AICA abend.
    
    Additional Symptom(s) Search Keyword(s): KIXREVWJB UAICA
    eyu0xqpq add_local_queue ntfylrt emassick emaswell
    

Local fix

  • LOCAL FIX:
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICSPlex SM V4R1M0 and V4R2M0 Users      *
    ****************************************************************
    * PROBLEM DESCRIPTION: Abend AICA may occur in a CMAS in       *
    *                      method EYU0XLNX (XLNX), or a method     *
    *                      called by XLNX, when a large number of  *
    *                      CPSM events (for example, EMASSICK,     *
    *                      EMASWELL) are being processed in a CMAS *
    *                      network in a short period of time.      *
    *                                                              *
    *                      This abend is more likely to occur in a *
    *                      CMAS that has no MASes connected to it. *
    ****************************************************************
    * RECOMMENDATION: After applying the PTF that resolves this    *
    *                 APAR, all CMASes must be restarted.  Note    *
    *                 that the restarts do not need to occur at    *
    *                 the same time.                               *
    ****************************************************************
    When an event is issued for a MAS, XLNX in the CMAS that is
    connected to the MAS will deliver the event locally to other
    methods and then issue a broadcast to deliver the event to all
    CMASes in the network that manage the CICSplex associated with
    the MAS.  XLNX will then run in the partner CMASes, delivering
    the event locally only.
    
    When a large number of events occur in a short period of time,
    it is possible that XLNX will be busy beyond the ICVR value for
    the CMAS.  Since the originating CMAS issues a broadcast which
    will cause the task to suspend, it will not AICA.  However, the
    partner CMASes do not issue a broadcast, and thus could abend
    AICA.
    

Problem conclusion

  • XLNX has been updated to call method EYU0XSSP (XSSP) to issue an
    EXEC CICS SUSPEND when processing a large number of events in a
    short period of time, if it does not issue a broadcast.
    

Temporary fix

  • FIX AVAILABLE BY PTF ONLY
    

Comments

APAR Information

  • APAR number

    PM48114

  • Reported component name

    CICS TS Z/OS V4

  • Reported component ID

    5655S9700

  • Reported release

    60M

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-09-19

  • Closed date

    2011-09-26

  • Last modified date

    2011-10-03

  • APAR is sysrouted FROM one or more of the following:

    PM48184

  • APAR is sysrouted TO one or more of the following:

    UK72174 UK72175

Modules/Macros

  •    EYU0XLNX
    

Fix information

  • Fixed component name

    CICS TS Z/OS V4

  • Fixed component ID

    5655S9700

Applicable component levels

  • R60M PSY UK72174

       UP11/09/28 P F109

  • R70M PSY UK72175

       UP11/09/28 P F109

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.1","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
03 October 2011