A fix is available
APAR status
Closed as program error.
Error description
DFHFC0002 ANQVSB A severe error (code X'042A') has occurred in module DFHFCDTS. 633 QR AP 042A FCDTS *EXC* SDTS-FAILED READ_INTO,DISASTER,,0,0,00000000,,LENGTH_OK,YES,NO =030570= AP 042A FCDTS *EXC* - SDTS-FAILED FUNCTION(READ_INTO) RESPONSE(DISASTER) REASON() MAXIMUM_RECORD_LENGTH(0) RECORD_LENGTH(0) ACCMETH_RETURN_CODE(00000000) DUPLICATE_KEY() LENGTH_ERROR_CODE(LENGTH_OK) TERMINATE_STRING(YES) TERMINATE_REMOTE_REQUEST(NO) 1-0000 00880000 00000038 00000000 00000000 0010 B46ED12E 7C800000 01000300 00000000 0020 00000000 D4C3D7E4 C1C4C1E3 00000000 0030 00000000 00000000 00000000 1B50DDD9 0040 000010D7 00000000 00000000 19C1E890 0050 00000000 00000000 9B50DDD9 00000000 0060 00000000 19C90700 00000000 00000000 0070 00000000 00000202 01000002 01020102 0080 00000200 0000C019 2-0000 0A800215 09000000 17EDB210 188C50F0 0010 9B50DDD9 1B50DDD9 000010D7 00000000 0020 00000000 00000000 * Data-2 offset 4 - errcode 09 means DTQ_NOT_PROGRAM_CALL EQU 9 = Not running as a PC routine The problem is that a request has come in to commit a change to SDT on a non-QR TCB while a concurrent local read request is being processed (under QR).
Local fix
n/a
Problem summary
**************************************************************** * USERS AFFECTED: All * **************************************************************** * PROBLEM DESCRIPTION: A severe error (code X'042A') in * * DFHFCDTS. * **************************************************************** * RECOMMENDATION: * **************************************************************** A request to commit changes to a user maintained data table was made from DFHFCRC, but the code failed to switch to the QR TCB before calling Shared Data Tables services (SDT is intended to be executed under QR only). If another request happened to be in SDT logic at the same time, executing under the QR TCB, then the code can fail with an apparent error code of 09, meaning DTQ_NOT_PROGRAM_CALL, and indicating the code was not called via a PC instruction. In fact this is a result of the logic being driven by the two TCBs simultaneously. KEYWORDS: ABENDAFCZ MSGDFHFC0002 FC0002 FC 0002 AFCZ DFHFC0002
Problem conclusion
UK67848 UK66252 DFHFCRC has been changed to ensure that it switches to the QR TCB before calling SDT services.
Temporary fix
FIX AVAILABLE BY PTF ONLY
Comments
APAR Information
APAR number
PM52565
Reported component name
CICS TS Z/OS V4
Reported component ID
5655S9700
Reported release
600
Status
CLOSED PER
PE
YesPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-11-18
Closed date
2012-01-11
Last modified date
2012-02-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
PM53485
Modules/Macros
DESFCRC DFHFCRC
Fix information
Fixed component name
CICS TS Z/OS V4
Fixed component ID
5655S9700
Applicable component levels
R600 PSY UK75374
UP12/01/27 P F201
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.1","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
02 February 2012