PM61962: MULTIPLE ABEND ASRAS IN EYU0WNAL

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Error Description￘
    After running for a while, multiple DFHAP0001 program checks
    (abend s0CC) occurred in CPSM environment.  The abending task
    was as follows:
    
      Meth Load-Pt  OPB      OSSB     Stack    Mal      MODB
      XLOP 000AAD28 229575B8 22957740 22957768 00000000 2120DE60
      WDTR 21FEB3C0 229575B8 22957740 229578B0 22957268 21219960
      WASV 21FF1098 229575B8 22957740 22957F88 22957A00 21219960
      WNAL 21FED560 229575B8 22957740 22958360 22958188 21219960
    
    
    This task abended 0CC (Exponent-Overflow Exception) in EYU0WNAL
    with the following psw and regs:
    
      PSW:  078D6000 A1FEDD52   IL  4  IC  0C
      GR 0-3 00000001  00000015  01704C00  21FED5A0
         4-7 208EFB90  01704D20  2255E438  2255EA44
         8-B 2255E148  01704B80  21FEE5A0  208EFA10
         C-F 22958188  22958360  00000000  00000017
      AR 0-3 00000000  00000000  01FF0030  00000000
         4-7 00000000  00000000  00000000  00000000
         8-B 00000000  01FF0030  00000000  00000000
         C-F 00000000  00000000  01FF0030  00000000
    
    The abend was occurring on an MD instruction:  6C00 9038 with
    Reg9 being the address of the (last) WAOW the MAS and offset 38
    the WAOW_ABND_FACTOR value.
    
    
    
    Additional Symptom(s) Search Keyword(s): KIXREVGJT
    

Local fix

  • Local Fix￘
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICSPlex SM V4R1M0 and V4R2M0 Users      *
    ****************************************************************
    * PROBLEM DESCRIPTION:    You are using CPSM's Workload Man-   *
    *                      agement with the Goal algorithm in a    *
    *                      large CICSplex spanning several LPARs.  *
    *                      You receive repeated abend ASRA (S0CC,  *
    *                      floating point overflow) in one or more *
    *                      routing regions.  The abends occur in   *
    *                      module EYU0WNAL (WNAL - Process WLM     *
    *                      Algorithm) at or near offset +7F2.      *
    ****************************************************************
    * RECOMMENDATION: After applying the PTF that resolves this    *
    *                 APAR, all MASes configured as WLM Routing    *
    *                 Regions must be recycled to pick up the new  *
    *                 code.  Note that the MASes do not need to    *
    *                 be brought down and restarted at the same    *
    *                 time.                                        *
    ****************************************************************
       When evaluating target regions for routing, module WNAL
    loops through initialized WLM AOR Work Elements (WAOWs) cal-
    culating the routing weight for each target region.  When
    using the Goal algorithm, targets are classified according to
    whether they are considered best able to meet service goals,
    executing in the best CEC, and executing in a CEC other than
    the best.  The base weight for targets not executing in the
    best CEC is stored in floating-point register 6.  After the
    base weight is determined and a factor is applied for abend
    compensation, the final weight is stored in the WLM Scope
    Vector Element (WSVE) for the region as both a normalized
    floating point value and as an integer.  A logic error in the
    conversion to integer resulted in the base weight for regions
    not executing in the best CEC being overlaid.  This value is
    then used as the base weight for the next region in the WAOW
    array and the process repeats.  If enough target regions are
    executing in CECs other than the best, the accumulated error
    might result in an exponent overflow when applying the abend
    compensation factor, or during the integer conversion.
    

Problem conclusion

  •    Module EYU0WNAL was modified to avoid overlaying the base
    weight for target regions not executing in the best CEC.
    

Temporary fix

  • FIX AVAILABLE BY PTF ONLY
    

Comments

APAR Information

  • APAR number

    PM61962

  • Reported component name

    CICS TS Z/OS V4

  • Reported component ID

    5655S9700

  • Reported release

    60M

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-04-05

  • Closed date

    2012-06-01

  • Last modified date

    2012-07-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK79270 UK79271

Modules/Macros

  •    CJA0WNAL CJB0WNAL CJC0WNAL EYU0WNAL
    

Fix information

  • Fixed component name

    CICS TS Z/OS V4

  • Fixed component ID

    5655S9700

Applicable component levels

  • R60M PSY UK79270

       UP12/06/07 P F206

  • R70M PSY UK79271

       UP12/06/07 P F206

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.1","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
02 July 2012