IBM Support

PI05492: AN ABEND (CODE 0C4/AKEA) HAS OCCURRED IN EXIT PROGRAM CIUXCCO1 AT EXIT POINT XEIIN.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • CICS IA 3.2 running the a series of ABEND0C4 abends occurred
    in many CICS regions and across several LPARs.
    Messages produced were :
    DFHAP0001 xxxxxxxx An abend (code 0C4/AKEA) has occurred at
    offset X'000000F2' in module CIUXCCO1.
    Getting the problem at the same time in 43 out of 70 regions
    where CICS IA is running
    .
    The 0c4 dump shows :
    Error occurred in program CIUXCCO1 at offset 000000F2 under the
    CICS RB in Basespace
    Execution key at Program Check/Abend:  8
    Instruction Length: 6   Interrupt Code: 0010   Exception
    Address: 300E0800
    PSW:  078D2000 297E22B2 Module CIUXCCO1 + X'F2'
          Failing instruction CLC 0(2,R2),3992(R5)
    CICS Registers:
    R0:  0CB24389  Module CEEPLPKA + X'18A389'
    R1:  285B3544  82123452 bytes of storage addressable
    R2:  300E0000  Storage invalid
    R3:  A97E21C0  Module CIUXCCO1 + X'0'
    R4:  00000000  2048 bytes of storage addressable
    R5:  297E31C0  Module CIUXCCO1 + X'1000'
    R6:  27E46D10  89907952 bytes of storage addressable
    R7:  00049004  7618556 bytes of storage addressable
    R8:  27E46F08  89907448 bytes of storage addressable
    R9:  00082134  Module DFHAIP + X'134'
    R10: 00000008  2040 bytes of storage addressable
    R11: A85B3544  82123452 bytes of storage addressable
    R12: 26CC9494  Task 00043 System EIB + X'0'
    R13: 27E46E70  89907600 bytes of storage addressable
    R14: A73EDD1A  Module DFHUEH + X'BFA'
    R15: A97E21C0  Module CIUXCCO1 + X'0'
    .
    R2 is bad ,loaded as an index register after a TRT instruction
    in CIUXCCO1.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICS Interdependency Analyzer V320       *
    *                 users.                                       *
    ****************************************************************
    * PROBLEM DESCRIPTION: INQUIRE WORKREQUEST and SET WORKREQUEST *
    *                      CICS commands issued by programs        *
    *                      working in the CICS region cause        *
    *                      an abend (code 0C4/AKEA) when you are   *
    *                      collecting Interdependency data.        *
    ****************************************************************
    * RECOMMENDATION: Apply the PTF.                               *
    ****************************************************************
    During XEIIN/XEIOUT processing the CIUXCCO1 exit program gets
    control. After execution of the TRT instruction
    (offset X'000000D8') register 2 contains an incorrect value if
    INQUIRE WORKREQUEST(B802) or SET WORKREQUEST(B804) CICS command
    is processing. Later a CLC instruction at offset X'000000F2'
    causes an abend (code 0C4/AKEA) because of incorrect address of
    the first operand evaluated based on register 2.
    The Translate table (TRT_TAB) in the CIUXCCOD copy needs to be
    corrected (offset  X'000000B8').
    

Problem conclusion

  • The Translate table (TRT_TAB) in the CIUXCCOD copy has been
    corrected at offset  X'000000B8' to avoid an abend
    (code 0C4/AKEA) in the CIUXCCO1 exit program.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI05492

  • Reported component name

    CICS INTER ANAL

  • Reported component ID

    5655U8600

  • Reported release

    320

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-11-05

  • Closed date

    2013-11-16

  • Last modified date

    2013-12-23

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI12659

Modules/Macros

  •    CIUXCCO1
    

Fix information

  • Fixed component name

    CICS INTER ANAL

  • Fixed component ID

    5655U8600

Applicable component levels

  • R320 PSY UI12659

       UP13/12/02 P F311

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSPPUS","label":"CICS Interdependency Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
23 December 2013