A fix is available
APAR status
Closed as program error.
Error description
CICS IA 3.2 running the a series of ABEND0C4 abends occurred in many CICS regions and across several LPARs. Messages produced were : DFHAP0001 xxxxxxxx An abend (code 0C4/AKEA) has occurred at offset X'000000F2' in module CIUXCCO1. Getting the problem at the same time in 43 out of 70 regions where CICS IA is running . The 0c4 dump shows : Error occurred in program CIUXCCO1 at offset 000000F2 under the CICS RB in Basespace Execution key at Program Check/Abend: 8 Instruction Length: 6 Interrupt Code: 0010 Exception Address: 300E0800 PSW: 078D2000 297E22B2 Module CIUXCCO1 + X'F2' Failing instruction CLC 0(2,R2),3992(R5) CICS Registers: R0: 0CB24389 Module CEEPLPKA + X'18A389' R1: 285B3544 82123452 bytes of storage addressable R2: 300E0000 Storage invalid R3: A97E21C0 Module CIUXCCO1 + X'0' R4: 00000000 2048 bytes of storage addressable R5: 297E31C0 Module CIUXCCO1 + X'1000' R6: 27E46D10 89907952 bytes of storage addressable R7: 00049004 7618556 bytes of storage addressable R8: 27E46F08 89907448 bytes of storage addressable R9: 00082134 Module DFHAIP + X'134' R10: 00000008 2040 bytes of storage addressable R11: A85B3544 82123452 bytes of storage addressable R12: 26CC9494 Task 00043 System EIB + X'0' R13: 27E46E70 89907600 bytes of storage addressable R14: A73EDD1A Module DFHUEH + X'BFA' R15: A97E21C0 Module CIUXCCO1 + X'0' . R2 is bad ,loaded as an index register after a TRT instruction in CIUXCCO1.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All CICS Interdependency Analyzer V320 * * users. * **************************************************************** * PROBLEM DESCRIPTION: INQUIRE WORKREQUEST and SET WORKREQUEST * * CICS commands issued by programs * * working in the CICS region cause * * an abend (code 0C4/AKEA) when you are * * collecting Interdependency data. * **************************************************************** * RECOMMENDATION: Apply the PTF. * **************************************************************** During XEIIN/XEIOUT processing the CIUXCCO1 exit program gets control. After execution of the TRT instruction (offset X'000000D8') register 2 contains an incorrect value if INQUIRE WORKREQUEST(B802) or SET WORKREQUEST(B804) CICS command is processing. Later a CLC instruction at offset X'000000F2' causes an abend (code 0C4/AKEA) because of incorrect address of the first operand evaluated based on register 2. The Translate table (TRT_TAB) in the CIUXCCOD copy needs to be corrected (offset X'000000B8').
Problem conclusion
The Translate table (TRT_TAB) in the CIUXCCOD copy has been corrected at offset X'000000B8' to avoid an abend (code 0C4/AKEA) in the CIUXCCO1 exit program.
Temporary fix
Comments
APAR Information
APAR number
PI05492
Reported component name
CICS INTER ANAL
Reported component ID
5655U8600
Reported release
320
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-11-05
Closed date
2013-11-16
Last modified date
2013-12-23
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI12659
Modules/Macros
CIUXCCO1
Fix information
Fixed component name
CICS INTER ANAL
Fixed component ID
5655U8600
Applicable component levels
R320 PSY UI12659
UP13/12/02 P F311
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSPPUS","label":"CICS Interdependency Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
23 December 2013