Error description
You are using the Command Flow Feature of CICS IA to analyze a long running task. You know the task issues multiple SYNCPOINTS, and were expecting the captured data to have multiple UOW_IDs associated with it, with a new UOW_ID assigned to entries after each SYNCPOINT. However, you only see one UOW_ID for the entire task. If you run a SELECT against the CIU_CMDFLOW_DATA table and it shows multiple SYNCPOINTS all with the same CICS_UOW value. The CICS_UOW value should change after each SYNCPOINT that is issued. Additional Symp tom(s) Search Keyword(s): KIXREVSVR
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: CICS IA 3.2 users who exploit the CICS IA * * Command Flow Data. * **************************************************************** * PROBLEM DESCRIPTION: The CICS IA Command Flow Data collector * * does not detect the changing of task * * UOW. So all collected records of the * * specific task have the same UOW. * **************************************************************** * RECOMMENDATION: Apply the PTF. * **************************************************************** Changing of task UOW occurs when EXEC CICS SYNCPOINT commands are issued. A syncpoint arises explicitly and implicitly. The CICS IA Command Flow Data collector currently considers all CICS command of the specific task as running within the scope of one UOW initiated at start transaction.
Problem conclusion
Code has been changed to provide detecting of the UOW changing.
Temporary fix
Comments
APAR Information
APAR number
PI20654
Reported component name
CICS INTER ANAL
Reported component ID
5655U8600
Reported release
320
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-06-24
Closed date
2014-09-17
Last modified date
2014-11-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI21839
Modules/Macros
CIUACM61 CIUBCXPI CIUXACE2 CIUXACL2 CIUXACO2 CIUXACO3 CIUXACR2 CIUXACR3 CIUXACT1 CIUXCCD1 CIUXCCE1 CIUXCCF1 CIUXCCF2 CIUXCCGA CIUXCCI1 CIUXCCL1 CIUXCCOA CIUXCCOE CIUXCCOG CIUXCCOL CIUXCCOW CIUXCCO1 CIUXCCP1 CIUXCCP2 CIUXCCRS CIUXCCR1 CIUXCCS1 CIUXCCW1 CIUXDB2A CIUXIMSA CIUXMQMA CIUXNATA CIUXNQED CIUZCCBA CIUZCCBB CIUZCCB1 CIUZCCFA CIUZCCF1 CIUZCCIC CIUZCCIR CIUZCCI1 CIUZCCML CIUZCCMS CIUZCCM1 CIUZCCOA CIUZCCOC CIUZCCOE CIUZCCOG CIUZCCOL CIUZCCOQ CIUZCCOR CIUZCCOS CIUZCCOW CIUZCCOY CIUZCCO1 CIUZCCXX CIUZCCX1 CIU53XPI CIU62XPI CIU63XPI CIU64XPI CIU65XPI CIU66XPI CIU67XPI
Fix information
Fixed component name
CICS INTER ANAL
Fixed component ID
5655U8600
Applicable component levels
R320 PSY UI21839
UP14/10/07 P F410
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSPPUS","label":"CICS Interdependency Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
04 November 2014