A fix is available
APAR status
Closed as program error.
Error description
Running CINC transaction to STOP Command Flow collector results in messages: CIU2239S CICS DISABLE EXITALL for program CIUXACO3 failed RESP=63 RCODE=800080 After restart Command Flow collector by CINC an Abend: DFHAP0701 A46L1A3C An abend (code 0C1/AKEA) has occurred in exit program CIUXACO3 at exit point XEIIN. The EC DISABLE PROGRAM request fails for the XEIIN global user exit with EIBRCODE X'800080' indicating the XEIIN is in use. The command flow collector after a subsequent START uses the old version of user exit program which contains wrong AUGW pointer. This is the reason of ABEND. Additional Symptom(s) Search Keyword(s): KIXREVWJB
Local fix
Keep manually issuing CINC to stop command flow collector until all exits are disabled.
Problem summary
**************************************************************** * USERS AFFECTED: All CICS IA v.3.2 users. * **************************************************************** * PROBLEM DESCRIPTION: Running CINC transaction to STOP * * Command Flow collector results in * * messages: CIU2239S CICS DISABLE * * EXITALL for program CIUXACO3 failed * * RESP=63 RCODE=800080 * * After restart Command Flow collector by * * CINC an Abend: DFHAP0701 A46L1A3C An * * abend (code 0C1/AKEA)has occurred in * * exit program CIUXACO3 at exit point * * XEIIN. The EC DISABLE PROGRAM request * * fails. For the XEIIN global user exit * * with EIBRCODE X'800080' indicating the * * XEIIN is in use. * * The command flow collector after a * * subsequent START uses the old version * * of user exit program which contains * * wrong AUGW pointer. * * This is the reason of ABEND. * **************************************************************** * RECOMMENDATION: Apply the PTF and execute HOLD actions. * **************************************************************** There is no reaction of the CICS IA, if exit is not stopped after DISABLE request in stress situation.
Problem conclusion
The DISABLE process is cycled as a five cycles loop. The loop continues, if exit is captured, but not more the five time. The same process is used in CINT.
Temporary fix
Comments
APAR Information
APAR number
PI20775
Reported component name
CICS INTER ANAL
Reported component ID
5655U8600
Reported release
320
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-06-25
Closed date
2014-09-16
Last modified date
2014-10-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI21365 PI27198
Modules/Macros
CIUACM71
Fix information
Fixed component name
CICS INTER ANAL
Fixed component ID
5655U8600
Applicable component levels
R320 PSY UI21365
UP14/10/01 P F409
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSPPUS","label":"CICS Interdependency Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
02 October 2014