A fix is available
APAR status
Closed as program error.
Error description
1. You run the CINC transaction and then choose the options to view the eligible applids for the command flow feature. The PF4 prompt on BMS map CIUA04 does not contain the CICS regions connecting using access method VTAM or IPCONNs. 2. CIUCNTL is defined in FOR region as local and remote in AOR. Running CINC transation to start the collection on FOR, message CIU2353E is issued. Running CINC on AOR all works fine. Additional Symptom(s) Search Keyword(s): KIXREVWJB ip sna lu62 link ciuacm31 CIU2304W CINC Collector is not stopped. There are no connected regions. This can occur if there are VTAM SNA connections present in the system which are not active.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All CICS IA Version 3.2 users. * **************************************************************** * PROBLEM DESCRIPTION: 1. CINT and CINC transactions do not * * support the managing of CICS regions * * connected via network access methods * * IP interconnectivity (IPIC) and * * intersystem communication * * (ISC) over SNA. * * * * 2. If the Command Flow Collector starts * * in AOR from FOR then it fails with * * message CIU2353E in TDQ. * **************************************************************** * RECOMMENDATION: Apply the PTF. * **************************************************************** 2. The reason is the incorrect check of INQUIRE results for the Control file data set name in AOR. CICS returns blanks in the AOR for the file defined in the FOR.
Problem conclusion
1. Code has been added to manage CICS regions connected via network access methods. 2. Code has been added to check the INQUIRE results for the blanks.
Temporary fix
Comments
**** AE12/05/31 FIX IN ERROR. SEE APAR PM65901 FOR DESCRIPTION **** PE12/08/22 FIX IN ERROR. SEE APAR PM71352 FOR DESCRIPTION
APAR Information
APAR number
PM51066
Reported component name
CICS INTER ANAL
Reported component ID
5655U8600
Reported release
320
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-10-27
Closed date
2012-05-21
Last modified date
2012-10-09
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK79034 UK79035 UK79036
Modules/Macros
CIUACM20 CIUACM30 CIUACM31 CIUACM60 CIUACM61 CIUACM70 CIUATM01 CIUATM02 CIUATM03 CIUA000C CIUA02E CIUA02K CIUA100C CIUA150C CIUA2HE CIUA2HK CIUA200C CIUA3HE CIUA3HK
SC34721100 |
Fix information
Fixed component name
CICS INTER ANAL
Fixed component ID
5655U8600
Applicable component levels
R32E PSY UK79035
UP12/08/07 P F208
R32K PSY UK79036
UP12/08/07 P F208
R320 PSY UK79034
UP12/08/07 P F208
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSPPUS","label":"CICS Interdependency Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
09 October 2012