Error description

  • No DB2 data collection occurs when running Tivoli Omegamon for
    CICS and monitoring DB2 in the region.  CICS tracing shows the
    DFHLDLDX IDENTIFY_PROGRAM XPI call  receives a response
    INSTANCE_NOT_FOUND which results in the CIUXCCR1 XRMIOUT GLUE
    bypassing the collection. A previous CICS AP 0100 user trace
    entry with OMEG_ENTRY contains the actual application R14
    value. CICS IA needs to be able to co-exist with Omegamon CICS
    DB2 monitoring.
    
    Additional Symptom(s) Search Keyword(s): KIXREVWJB
    

Local fix

  • Run the OMEG transaction with the SHUT option to terminate DB2
    monitoring for Omegamon.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: CICS IA 3.2 users who exploit Omegamon CICS  *
    *                 to monitor DB2/MQ/IMS.                       *
    ****************************************************************
    * PROBLEM DESCRIPTION: CICS IA does not collect DB2/MQ/IMS     *
    *                      data if Omegamon CICS is also           *
    *                      running and monitoring DB2/MQ/IMS       *
    *                      in the region.                          *
    ****************************************************************
    * RECOMMENDATION: Apply the PTF.                               *
    ****************************************************************
    CICS tracing shows the DFHLDLDX IDENTIFY_PROGRAM XPI call
    receives a response INSTANCE_NOT_FOUND which results in the
    CIUXCCR1 XRMIOUT GLUE bypassing the collection.  A previous
    CICS AP 0100 user trace entry with OMEG_ENTRY contains the
    actual application R14 value.  CICS IA needs to be able to
    co-exist with Omegamon CICS DB2/MQ/IMS monitoring.
    

Problem conclusion

  • Code of the CIUXCCR1 has been changed (based on technote
    # 1593318) to find the actual application R14 value before
    calling DFHLDLDX IDENTIFY_PROGRAM XPI when Omegamon is also
    running.
    CICS IA now collects data of DB2/MQ/IMS calls, not with command
    flow feature, when Omegamon runs.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM65709

  • Reported component name

    CICS INTER ANAL

  • Reported component ID

    5655U8600

  • Reported release

    320

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-05-29

  • Closed date

    2012-06-08

  • Last modified date

    2014-01-21

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK79463

Modules/Macros

  •    CIUXCCR1
    

Fix information

  • Fixed component name

    CICS INTER ANAL

  • Fixed component ID

    5655U8600

Applicable component levels

  • R320 PSY UK79463

       UP12/08/31 P F208

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSPPUS","label":"CICS Interdependency Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
21 January 2014