Error description
You may receive the following message when collecting dependency data for IMS. DFHAP0701 applid An abend (code 0C4/AKEA) has occurred in exit program CIUXCCL1 at exit point XDLIPOST. The failure occurs due to the UIB contaiing residual data. UIBFCTR is x'08'INVREQ and UIBDLTR is also x'08'FUNCNS. In this case the request was not scheduled and the UIBPCBAL may be residual. CIUXCCL1 goes to label XDFL2 as the PAPL is for a "GU" function for the CALLDLI. It then proceeds to XDLCONT and the 0C4s at label MVCALL1 as the R3 value from parameter 2 is not addressable due to the failure of the call. The CIUXCCL1 XDLIPOST GLUE needs to check for the existence of a UIB and then check the UIBFCTR for a zero return code and if not, we should return and not attempt collection from the PAPL as we cannot be sure we can access parameter 2 data which may not have been set by DBCTL. Additional Symptom(s) Search Keyword(s): KIXREVWJB CALLDLI UIB UEPUIBX UEPUIB UEPAPLIST ABENDS0C4 S0C4 MS/DFHAP0701
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of CICS IA version 3.2 * **************************************************************** * PROBLEM DESCRIPTION: When the CICS IA interdependency * * collector collects dates from * * XDLIPOST exit in high-usage system * * The ABEND S0C4 from CIUCXXL1 CICS * * IA exit module can occur. * **************************************************************** * RECOMMENDATION: Apply PTF. * **************************************************************** When the CICS IA interdependency collector collects IMS requests the ABEND S0C4 can sometimes occurs from CIUXCCL1 module, if it attempts to read a program name by using the pointer to UIB from UEPAPLIST, because this pointer is irrelevant at this moment.
Problem conclusion
The exit program CIUXCCL1 checks UEPUIBX against UEPUIB1 and reads a program name by using the pointer to UIB from UEPAPLIST if UEPUIBX EQ UEPUIB1 only.
Temporary fix
Comments
APAR Information
APAR number
PM65908
Reported component name
CICS INTER ANAL
Reported component ID
5655U8600
Reported release
320
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-05-31
Closed date
2012-09-28
Last modified date
2012-11-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK82317
Modules/Macros
CIUXCCL1
Fix information
Fixed component name
CICS INTER ANAL
Fixed component ID
5655U8600
Applicable component levels
R320 PSY UK82317
UP12/10/10 P F210
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSPPUS","label":"CICS Interdependency Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
02 November 2012