A fix is available
APAR status
Closed as program error.
Error description
When CICS IA affinity collector was running CICS TS 4.2 abended with 0C4/AKEA in user exit program CIUZCCI1
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All CICS IA 3.2 users. * **************************************************************** * PROBLEM DESCRIPTION: Some SLL instructions generated by PL/X * * compiler contain B2 register not equal * * 0 where must be 0. * **************************************************************** * RECOMMENDATION: Apply the PTF. * **************************************************************** Format of SLL instruction is 'SLL R1,D2(B2)'. PL/X compiler generates SLL instructions for example 'SLL 3,4'. We expect that assembler interprets it as 'SLL 3,4(0)' but we see 'SLL 3,4(N)'. Where 'N' is not null register. So in a few instances R1 will be shifted left the number of more then 4 bits. It happens because of some 'USING BASE,N' assembler instructions in PL/X programs do not have the related DROP 'N' instructions. Assembler instructions after that point are using register N where we would normally expect to see register 0.
Problem conclusion
Missing DROP assembler instructions was added.
Temporary fix
Comments
APAR Information
APAR number
PM67366
Reported component name
CICS INTER ANAL
Reported component ID
5655U8600
Reported release
320
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-06-21
Closed date
2012-07-09
Last modified date
2012-08-09
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK80183
Modules/Macros
CIUA110C CIUA140C CIUA180C CIUXCCGA CIUXCCOA CIUXCCOE CIUXCCOG CIUXCCOL CIUXCCOW CIUXCCRS CIUXDB2A CIUXIMSA CIUXMQMA CIUXNATA CIUZCCBA CIUZCCBB CIUZCCFA CIUZCCIC CIUZCCIR CIUZCCML CIUZCCMS CIUZCCOA CIUZCCOC CIUZCCOE CIUZCCOG CIUZCCOL CIUZCCOQ CIUZCCOR CIUZCCOS CIUZCCOW CIUZCCOY CIUZCCXX
Fix information
Fixed component name
CICS INTER ANAL
Fixed component ID
5655U8600
Applicable component levels
R320 PSY UK80183
UP12/07/14 P F207
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSPPUS","label":"CICS Interdependency Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]