Error description
You shut down your CMAS and abend S00C4 occurs in EYU0CRCK at offset x'714'. Failing instruction is 58F0 F000, L R15,RACR_XSECBREN Reg15 is loaded from RegB+984 ( MOEB field SEC_XSEC_STRUCT ). The reg15 address is no longer in storage. In this case, an XLST task is in processing a request for the CMAS base table and a security check is made. However, the security subtask has quiesced due to the shutdown and has not updated the MOEB to remove the address to its control block. Additional Symptom(s) and Keyword(s): 5697E9301 R300 300 230 5697E9301 R300 300 230 EYUXL0900I Starting Environment Recovery EYUXL0905E CMASMP ASRA IN CRCK, OFFSET 00000714 PSW=470C2000 A EYUXL0905E INTC=0011 ILC=4 TXCP=25E74000 SCODE=S00C4 TRAN=XLST TASK=0000355 EYUXL0905E INTC=0011 ILC=4 TXCP=25E74000 SCODE=S00C4 TRAN=XLST EYUXL0905E Methods=CRCK,XLSD,XLSI,XLST,XLOP EYUXL0906I Registers at ABEND EYUXL0907I GPR0-3 00000002 29200F18 28D83C0B 28D81660 EYUXL0907I GPR4-7 28D82660 281C2950 293DD398 28D83B90 EYUXL0907I GPR8-B 292010A0 292002CC 293DDA30 00160010 EYUXL0907I GPRC-F 293DE9E8 29200170 A8D81CEC 25E74FD0 EYUXL0908I Storage At ABEND EYUXL0909I -20 DDAB9210 DDAD4110 DDA858F0 D09458FF EYUXL0909I -10 00040DEF 4DE04A7E BFFFB984 50F0D744 EYUXL0909I +00 58F0F000 4110D6D0 0DEF4DE0 4A4047F0 EYUXL0909I +10 36B2D203 D71C4844 D203D720 4848D727
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All CICSPlex SM V3R1M0 Users. * **************************************************************** * PROBLEM DESCRIPTION: An ABEND ASRA (S0C4) may occur at * * offset x'6D4' in EYU0CRCK during CMAS * * shutdown. * * * * The abend is more likely to occur if * * API/WUI or EUI requests are still being * * processed when the CMAS is shutdown. * **************************************************************** * RECOMMENDATION: After applying the PTF that resolves this * * APAR, all CMASes must be recycled to pick * * up the new code. Note that the restarts * * do not need to be done at the same time. * **************************************************************** During CMAS initialization, CICSPlex SM establishes a subtask running program EYU9XSEC (XSEC - External Security Interface). XSEC is responsible for making all calls to the External Security Manager. EYU0CRCK (CRCK - Communications Security Access Check) is called to perform security checking in a CMAS. CRCK calls XSEC via a branch entry interface. During a CMAS shutdown, it is possible for the XSEC subtask to terminate before all tasks which may call CRCK are complete. If this happens, the reported abend may occur.
Problem conclusion
EYU0CRLT (CRLT - Security Services Long-Running Task) has been changed so that it no longer posts XSEC to terminate. Instead it indicates that the security interface is no longer available. Macro EYUBCRRR, which is used by CRCK and other methods to invoke XSEC, has been changed to abort processing if Communications termination is in progress. EYU9XSTC (XSTC - Interval Timing Control Task) has been changed to issue new message EYUXS1013I when XSEC has terminated. XSEC has been changed to update the XECB when it terminates normally. Additionally an error which may prevent XSEC from releasing its stack storage has been corrected.
Temporary fix
FIX AVAILABLE BY PTF ONLY
Comments
APAR Information
APAR number
PK07159
Reported component name
CPSM CICS 3.1
Reported component ID
5655M1501
Reported release
100
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2005-06-13
Closed date
2005-07-25
Last modified date
2005-11-21
APAR is sysrouted FROM one or more of the following:
PK02960
APAR is sysrouted TO one or more of the following:
UK05634
Modules/Macros
EYUBCRRR EYU0CRCK EYU0CRDK EYU0CRLT EYU0CRSI EYU9XSEC EYU9XSTC
GC34647100 |
Fix information
Fixed component name
CPSM CICS 3.1
Fixed component ID
5655M1501
Applicable component levels
R100 PSY UK05634
UP05/07/27 P F507
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
22 February 2023