A fix is available
APAR status
Closed as program error.
Error description
When the local time offset is changed (as is frequently done for a summertime 'spring forward' or wintertime 'fall back' time change), an EXEC CICS or CEMT PERFORM RESET is necessary to make CICS aware of the change in the local time offset. If no PERFORM RESET is done, then Interval Control STARTs that specify an explicit time will expire at the wrong time. (They will expire at the old local time.) And CICS-generated time stamps in messages and CEMT displays and EIBTIME will also reflect the old local time. These are normal and expected consequences of not doing the PERFORM RESET . But in the case where the local time is moved back an hour (i.e. the local time offset from GMT goes from say -5 to -6 or from +3 to +2), interval control will stop working for EXEC CICS START and DELAY commands that specify an INTERVAL. This will happen at the 1st new local midnight following the change in local time offset. For the next 23 hours, CSATODP will be stuck at 2400000F and Interval Control commands will not work. (At any time, however, a PERFORM RESET command will make everything work again.) The same problem also happens on a summertime 'spring forward' change. But the problem only happens for the 1 hour prior to new local midnight (starting with the 2nd new local midnight after the time change.)
Local fix
Do a CEMT PERFORM RESET
Problem summary
**************************************************************** * USERS AFFECTED: All CICSPlex/SM V3R1M0 Users * **************************************************************** * PROBLEM DESCRIPTION: The CICS time-of-day becomes frozen and * * Interval Control stops working if * * PERFORM RESET is not issued after * * setting clocks forward or back to * * adjust for Summer or Winter time. * **************************************************************** * RECOMMENDATION: If any sample JCL that has been modified by * * this PTF is used, then you must restart the * * corresponding CMAS and/or MAS. * * * * NOTE: CICS Transaction Server for z/OS PTF * * UK06715 must be installed before attempting * * to use the samples updated by this PTF. * **************************************************************** This PTF is to exploit the AUTORESETTIME=YES System Initialization parameter.
Problem conclusion
CMAS IVP (Installation Verification Procedure) JCL, sample CICS Transaction Server parameters to initialize a CMAS, and CMAS Starter set JCL have been updated to include AUTORESETTIME=YES. Additionally, this PTF updates the CICSPlex SM for CICS TS z/OS, Web User Interface Guide, and the CICS Transaction Server for z/OS Installation Guide.
Temporary fix
FIX AVAILABLE BY PTF ONLY
Comments
APAR Information
APAR number
PK10629
Reported component name
CPSM CICS 3.1
Reported component ID
5655M1501
Reported release
100
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2005-08-19
Closed date
2005-10-13
Last modified date
2005-11-03
APAR is sysrouted FROM one or more of the following:
PK10236
APAR is sysrouted TO one or more of the following:
UK08092
Modules/Macros
EYUC64I0 EYUICM1A EYUICM1B EYUJCM1A EYUJCM1B
GC34642601 |
Fix information
Fixed component name
CPSM CICS 3.1
Fixed component ID
5655M1501
Applicable component levels
R100 PSY UK08092
UP05/10/16 P F510
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: