Error description

  • When you pick the 'Close Window' link from the navigation frame
    in the Web User Interface (WUI), the browser sends a URL back to
    the WUI server to mark this window CLOSED.  The resources
    associated with the window are freed in the server.  The
    EYUVC1214E is sent back to the browser letting them know that
    they should close the window.
    The message is misleading in that the browser window remains
    open.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICSPlex SM V3R1M0 Users.                *
    ****************************************************************
    * PROBLEM DESCRIPTION: - The 'Close Window' hyperlink          *
    *                        contained on the CICSPlex SM Web User *
    *                        Interface (WUI) Navigation frame does *
    *                        not close the browser window.         *
    *                                                              *
    *                        When this hyperlink is used, message: *
    *                                                              *
    *                         EYUVC1214E Window closed.            *
    *                                                              *
    *                        is displayed in the Web browser       *
    *                        window.                               *
    *                                                              *
    *                      - WUI View Editor users may receive     *
    *                        message:                              *
    *                                                              *
    *                         EYUVE0370E Unable to edit View set   *
    *                                    (<object>) as it is       *
    *                                    already being updated by  *
    *                                    another user (<userid>).  *
    *                                    Please select another     *
    *                                    View set name for edit.   *
    *                                                              *
    *                        or message:                           *
    *                                                              *
    *                         EYUVE0051E Unable to edit Menu       *
    *                                    (<object>) as it is       *
    *                                    already being updated by  *
    *                                    another user (<userid>).  *
    *                                    Please select another     *
    *                                    Menu name for edit.       *
    *                                                              *
    *                        when attempting to edit a View set or *
    *                        Menu that was previously being        *
    *                        edited.                               *
    *                                                              *
    *                        This problem occurs if the user       *
    *                        closes a browser window (via the      *
    *                        'Close Window' hyperlink or Web       *
    *                        browser window controls) that         *
    *                        contains an unsaved View set or Menu. *
    ****************************************************************
    * RECOMMENDATION: After applying the PTF that resolves this    *
    *                 APAR, all Web User Interface Servers must    *
    *                 be recycled to pick up the new code. Note    *
    *                 that the restarts do not need to be done at  *
    *                 the same time.                               *
    ****************************************************************
    - Neither the 'Close Window' hyperlink or the 'Window closed'
      response sent to the browser will attempt to close the Web
      browser window displayed on the users desktop.
    
    - When the WUI receives a 'Close Window' request, method
      EYU0VISL is invoked in the WUI Server to update the WUI
      control blocks associated with the browser window so that they
      are eligible for 'Housekeeping' or 'Garbage Collection'.  This
      'Housekeeping' runs periodically in the WUI, to free resources
      associated with dormant windows. Until these resources are
      freed, WUI objects will remain allocated to the window, and
      therefore not available for other windows or users to edit.
    

Problem conclusion

  • - The HTML used to generate the 'Close Window' hyperlink has
      been changed to invoke a JavaScript function in order to
      attempt to close the Web browser window. This will only
      function on a JavaScript enabled Web browser.
    
    - EYU0VISL has been updated to perform the 'Housekeeping' of
      closed windows immediately.
    

Temporary fix

  • FIX AVAILABLE BY PTF ONLY
    

Comments

  • - The 'Close Window' hyperlink
      contained on the CICSPlex SM Web User
      Interface (WUI) Navigation frame does
      not close the browser window.
    
      When this hyperlink is used, message:
    
       EYUVC1214E Window closed.
    
      is displayed in the Web browser
      window.
    
    - WUI View Editor users may receive
      message:
    
       EYUEVE0370E Unable to edit View set
                   (<object>) as it is
                   already being updated by
                   another user (<userid>).
                   Please select another
                   View set name for edit.
    
      or message:
    
       EYUEVE0051E Unable to edit Menu
                   (<object>) as it is
                   already being updated by
                   another user (<userid>).
                   Please select another
                   Menu name for edit.
    
      when attempting to edit a View set or
      Menu that was previously being
      edited.
    
      This problem occurs if the user
      closes a browser window (via the
      'Close Window' hyperlink or Web
      browser window controls) that
      contains an unsaved View set or Menu.
    
    - Neither the 'Close Window' hyperlink or the 'Window closed'
      response sent to the browser will attempt to close the Web
      browser window displayed on the users desktop.
    
    - When the WUI receives a 'Close Window' request, method
      EYU0VISL is invoked in the WUI Server to update the WUI
      control blocks associated with the browser window so that they
      are eligible for 'Housekeeping' or 'Garbage Collection'.  This
      'Housekeeping' runs periodically in the WUI, to free resources
      associated with dormant windows. Until these resources are
      freed, WUI objects will remain allocated to the window, and
      therefore not available for other windows or users to edit.
    
    - The HTML used to generate the 'Close Window' hyperlink has
      been changed to invoke a JavaScript function in order to
      attempt to close the Web browser window. This will only
      function on a JavaScript enabled Web browser.
    
    - EYU0VISL has been updated to perform the 'Housekeeping' of
      closed windows immediately.
    

APAR Information

  • APAR number

    PK18912

  • Reported component name

    CPSM CICS 3.1

  • Reported component ID

    5655M1501

  • Reported release

    100

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2006-01-31

  • Closed date

    2006-03-08

  • Last modified date

    2006-04-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK12409

Modules/Macros

  •    DYU0VISD DYU0VISL DYU0VPNF EYUEVPNF EYUKVPNF
    EYURVPNF EYUSVPNF EYU0VISD EYU0VISL EYU0VPNB EYU0VPNE
    

Fix information

  • Fixed component name

    CPSM CICS 3.1

  • Fixed component ID

    5655M1501

Applicable component levels

  • R100 PSY UK12409

       UP06/03/14 P F603

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
22 February 2023