IBM Support

PK22274: AICA ABEND IN XDQA OFFSET 00000C3C XDNR

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Abend AICA in EYU0XDQA XDQA offset x'C3C' occurs when
    you run a CPSM API program that performed a COPY for a
    very large result set.
    
    Additional Symptoms and Kewords:
    EYUXL0905E FF5ACCM AICA IN XDQA, OFFSET 00000C3C PSW=078D6000
    B2C87E84
    EYUXL0905E INTC=0001 ILC=2 TXCP=00000000 SCODE=S???? TRAN=XDNR
    TASK=0090046
    EYUXL0905E Methods=XDQA,XDY2,XDNR,XLOP
    EYUXL0906I Registers at ABEND
    EYUXL0907I GPR0-GPR3 00035C78 00028710 0353A140 32C87288
    EYUXL0907I GPR4-GPR7 00000000 00749618 0353A8E8 05791234
    EYUXL0907I GPR8-GPRB 00005F0B 056EAC00 00028600 32C87249
    EYUXL0907I GPRC-GPRF 332AC200 32A4EF70 00004058 05720894
    EYUXL0907I ARR0-ARR3 00000000 01FF001C 01FF001C 00000000
    EYUXL0907I ARR4-ARR7 01FF001C 01FF001C 01FF001C 01FF001C
    EYUXL0907I ARR8-ARRB 00000000 01FF001C 01FF001C 00000000
    EYUXL0907I ARRC-ARRF 00000000 00000000 01FF001C 01FF001C
    EYUXL0908I Storage At ABEND
    EYUXL0909I -20 50209048 58E0A01C 51F09100 1F444340
    EYUXL0909I -10 F0000640 89400005 5114A110 9A441000
    EYUXL0909I +00 58401004 1F11BF17 F0014780 3C940610
    EYUXL0909I +10 5800A108 1C001A41 41440040 180F1B09
    EYUXL0910I EYU9XLRV
    Dump,CPSMPC50,CPSMPC50,P005,CMAS,XDNR,0090046,AICA,EYU0XDQA
    EYUXL0999I XLRV Exiting Successfully
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICSPlex/SM V3R1M0 Users                 *
    ****************************************************************
    * PROBLEM DESCRIPTION:    When executing a CPSM API program    *
    *                      which uses the COPY command to copy a   *
    *                      large result set, you may receive an    *
    *                      abend AICA in method XDY2 (EYU0XDY2 -   *
    *                      API COPY Command), or in a method (for  *
    *                      example XDQA (EYU0XDQA - Add Records    *
    *                      to Result Set)) called from XDY2.       *
    ****************************************************************
    * RECOMMENDATION: After applying the PTF that resolves this    *
    *                 APAR, all CMASes must be recycled to pick    *
    *                 up the new code.  Note that the restarts     *
    *                 do not need to be done at the same time.     *
    ****************************************************************
       Module EYU0XDY2 copies a CPSM API Result Set, with optional
    filtering of records, to a new Result Set.  For a large result
    set, this may result in abend AICA in XDY2, or in a method
    called from XDY2, as XDY2 invokes no CICS services which would
    cause the task to be suspended.
    

Problem conclusion

  •    Module EYU0XDY2 was modified to retrieve the runaway task
    interval from CICS.  A timer is set before starting the copy
    process for a result set, and is tested after each record is
    processed.  If the elapsed time exceeds 50% of the runaway
    task interval the task is suspended, and the timer is reset.
       Changes were also made to comply with CPSM standards for
    trace level usage within API command processors.
    

Temporary fix

  • FIX AVAILABLE BY PTF ONLY
    

Comments

APAR Information

  • APAR number

    PK22274

  • Reported component name

    CPSM CICS 3.1

  • Reported component ID

    5655M1501

  • Reported release

    100

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2006-03-28

  • Closed date

    2006-04-07

  • Last modified date

    2006-05-01

  • APAR is sysrouted FROM one or more of the following:

    PK22336

  • APAR is sysrouted TO one or more of the following:

    UK13280

Modules/Macros

  •    EYU0XDY2
    

Fix information

  • Fixed component name

    CPSM CICS 3.1

  • Fixed component ID

    5655M1501

Applicable component levels

  • R100 PSY UK13280

       UP06/04/11 P F604

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]