IBM Support

PH12252: CDI CANNOT FUNCTION WITH PER MODULE HOT RESTARTS. CURRENTLY IT DISABLES THEM ON ANY APP WHERE CDI IS ENABLED

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Rather than disabling per module restarts when CDI is enabled
    (defaults to true on all apps) we will disable module restarts
    on applications where a CDI bean has been discovered.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:  All users of IBM WebSphere Application      *
    *                  Server                                      *
    ****************************************************************
    * PROBLEM DESCRIPTION: CDI always disables per module          *
    *                      restarts                                *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    CDI cannot handle a per module restart so it sets a flag
    requiring the entire application to restart when a single
    module was updated. However it set this flag on applications
    where it looked for CDI beans even where if finds none.
    

Problem conclusion

  • The code that sets the flag which disables per module resarts
    was moved to after the bean scanning has concluded and will
    only fire if a bean was found.
    
    The fix for this APAR is currently targeted for inclusion in
    fix pack 9.0.5.0.  Please refer to the Recommended Updates
    page for delivery information:
    http://www.ibm.com/support/docview.wss?rs=180&uid=swg27004980
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH12252

  • Reported component name

    WEBSPHERE APP S

  • Reported component ID

    5724J0800

  • Reported release

    900

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-05-21

  • Closed date

    2019-06-27

  • Last modified date

    2019-06-27

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WEBSPHERE APP S

  • Fixed component ID

    5724J0800

Applicable component levels

  • R900 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSEQTP","label":"WebSphere Application Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.0","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
02 November 2021