  • Closed as program error.

Error description

  • If groupSecurityNameMapping propertyForInput is set as
    "uniqueName" and propertyForOutput is "cn" in realm
    configuration, if getGroups is called with uniqueName as value
    then cn value is not returned in results
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:  All users of IBM WebSphere Application      *
    *                  Server V8.0 and V8.5                        *
    ****************************************************************
    * PROBLEM DESCRIPTION: VMM getGroups call with uniqueName as   *
    *                      value is not returning                  *
    *                      propertyForOutput property value.       *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    If getGroups is called with uniqueName as value, if
    groupSecurityNameMapping propertyForInput is set as
    "uniqueName" and propertyForOutput is "cn" in realm
    configuration, then VMM is not returning propertyForOutput
    property cn value in output dataobject.
    

Problem conclusion

  • This fix corrects the code to handle propertyForOutput and
    return in getGroups call output dataobject
    
    The fix for this APAR is currently targeted for inclusion in
    fix packs 8.0.0.10 and 8.5.5.4.  Please refer to the
    Recommended Updates page for delivery information:
    http://www.ibm.com/support/docview.wss?rs=180&uid=swg27004980
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI18109

  • Reported component name

    WEBS APP SERV N

  • Reported component ID

    5724H8800

  • Reported release

    850

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-05-16

  • Closed date

    2014-07-25

  • Last modified date

    2014-07-25

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WEBS APP SERV N

  • Fixed component ID

    5724H8800

Applicable component levels

  • R800 PSY

       UP

  • R850 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSEQTP","label":"WebSphere Application Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.5","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
28 April 2022