IBM Support

PI27526: THE @PRODUCES ANNOTATION METHOD ON CLASS RESULTS IN A NON-NULL INJECTIONPOINT INSTANCE ON FIRST INVOCATION.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The @Produces annotation method on class results in a non-NULL
    injectionpoint instance on the first invocation.   Subsequent
    calls of the method in which the injectionpoint is called will
    show that the injectionpoint instance is null.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:  All users of IBM WebSphere Application      *
    *                  Server V8.0 and v8.5 using CDI              *
    ****************************************************************
    * PROBLEM DESCRIPTION: The @Produces annotation method on      *
    *                      class results in a non-NULL             *
    *                      injectionpoint instance on the first    *
    *                      invocation.                             *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    If a Contextual Bean Reference is obtained programmatically
    via the BeanManager interface and that Bean is created using
    an @Producer method which includes an @InjectionPoint injected
    parameter, then that injected InjectionPoint should be
    null.
    In some cases it is not null and an InjectionPoint
    instance is incorrectly injected.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    PI27526

  • Reported component name

    WEBSPHERE FOR Z

  • Reported component ID

    5655I3500

  • Reported release

    800

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-10-13

  • Closed date

    2015-01-08

  • Last modified date

    2015-01-08

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WEBSPHERE FOR Z

  • Fixed component ID

    5655I3500

Applicable component levels

  • R800 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS7K4U","label":"WebSphere Application Server for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"800","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date: