PI42046: Datasource TestConnection through wsadmin can result in a failure after a client reroute warning

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Test connection through wsadmin can fail if a client re-route
    occurs during the testConnection due to the warning :
    0000004b DSConfigurati W   DSRA8043W: The database connection
    has been rerouted.
    
    wsadmin>AdminControl.testConnection(AdminConfig.getid('/DataSour
    ce:db2ds/'))
    'WASX7388E: Connection to provided datasource failed.'
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:  All users of IBM WebSphere Application      *
    *                  Server V8.0 and V8.5                        *
    ****************************************************************
    * PROBLEM DESCRIPTION: Datasource TestConnection through       *
    *                      wsadmin can result in a failure after   *
    *                      a client reroute                        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    When doing the testConnection from wsadmin against a
    datasource with the primary database down, the testConnection
    operation is reported as failed as below :
    wsadmin>AdminControl.testConnection(AdminConfig.getid('/DataSour
    ce:db2ds/'))
    'WASX7388E: Connection to provided datasource failed.'
    During the testConnection operation, when the connection gets
    re-routed to the secondary database, the WebSphere RRA
    (adapter) component logs the warning DSRA8043W to indicatate
    that the connection has been re-routed. This warning is
    considered as a failure and hence the wsadmin treats the
    warning as a failure.
    

Problem conclusion

  • The WebSphere RRA (adapter) component has been updated to
    ensure that the client re-route warning does not impact the
    testConnection outcome.
    The fix for this APAR is currently targeted for inclusion in
    fix packs 8.0.0.12 and 8.5.5.8.  Please refer to the
    Recommended Updates page for delivery information:
    http://www.ibm.com/support/docview.wss?rs=180&uid=swg27004980
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI42046

  • Reported component name

    WEBS APP SERV N

  • Reported component ID

    5724H8800

  • Reported release

    800

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2015-05-29

  • Closed date

    2015-09-21

  • Last modified date

    2015-09-21

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WEBS APP SERV N

  • Fixed component ID

    5724H8800

Applicable component levels

  • R800 PSY

       UP

  • R850 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSEQTP","label":"WebSphere Application Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.0","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
27 April 2022