Error description

  • javax.management.InstanceNotFOundException was thrown when
    performing an ear expansion to its binary location in a z/OS
    environment with the server being shutdown.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:  All users of IBM WebSphere Application      *
    *                  Server 8.5.5.                               *
    ****************************************************************
    * PROBLEM DESCRIPTION: Application distribution failed for an  *
    *                      application update when an application  *
    *                      MBean method call failed on z/OS.       *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Application distribution failed for an application update on
    z/OS with the following scenario:
     óÔÇö ¥performed update to a group of running applications
     óÔÇö ¥saved the configuration
     óÔÇö ¥stopped the server where the applications were running wh
    the application distribution was still going on
    The server stop killed the servant region of the server but not
    the application MBeans, which resided in the control region.
    As a result, when an application MBean was queried, the MBean
    belonging to the application was returned. However, a
    subsequent call to its method failed with
    javax.management.InstanceNotFoundException on the servant.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    PI49211

  • Reported component name

    WEBS APP SERV N

  • Reported component ID

    5724H8800

  • Reported release

    850

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2015-09-23

  • Closed date

    2015-10-27

  • Last modified date

    2015-10-27

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WEBS APP SERV N

  • Fixed component ID

    5724H8800

Applicable component levels

  • R850 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSEQTP","label":"WebSphere Application Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.5","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
28 April 2022