IBM Support

PM47409: FIX INTERNAL FATAL ERROR (IXJXE0678E [ERR 0614]

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Under certain circustances stylesheet compilation could fail
    with the message
    
    FATAL ERROR: IXJXE0678E: [ERR 0614] The processor has
    encountered an internal error condition. Please report the
    problem and provide the following information: We shouldn't
    leave more than one item on the FCG codegen stack.
    
    This was due to an unexpected interaction of two optimizers.
    The compiler has been corrected, which should eliminate this
    error case and may produce slightly faster execution.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:  All users of IBM WebSphere Application      *
    *                  Server V8.0                                 *
    ****************************************************************
    * PROBLEM DESCRIPTION: Under certain circustances stylesheet   *
    *                      compilation could fail with the         *
    *                      message                                 *
    *                      FATAL ERROR: IXJXE0678E: [ERR 0614]     *
    ****************************************************************
    * RECOMMENDATION:  Install a fix pack that contains this       *
    *                  APAR.                                       *
    ****************************************************************
    FATAL ERROR: IXJXE0678E: [ERR 0614] The processor has
    encountered an internal error condition. Please report the
    problem and provide the following information: We shouldn't
    leave more than one item on the FCG codegen stack.
    This was due to an unexpected interaction of two optimizers --
    essentially, one failed to allow for the loop refactoring
    performed by the other. Since the number of arguments
    passed and returned was different in the two cases, this
    oversight resulted in a call being incompatible with the
    function it called, which we detected and reported when we
    started to convert the IL representation into executable code.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    PM47409

  • Reported component name

    WEBS APP SERV N

  • Reported component ID

    5724H8800

  • Reported release

    800

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-09-08

  • Closed date

    2011-10-21

  • Last modified date

    2011-10-21

  • APAR is sysrouted FROM one or more of the following:

    PM47404

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WEBS APP SERV N

  • Fixed component ID

    5724H8800

Applicable component levels

  • R800 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSEQTP","label":"WebSphere Application Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.0","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date: