Fixes are available
APAR status
Closed as program error.
Error description
Liberty profile is unable to parse configured values for the expiration attribute of the ltpa configuration element which include time units such as m (minutes) or h (hours).
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IBM WebSphere Application * * Server Liberty Profile using LTPA * **************************************************************** * PROBLEM DESCRIPTION: Liberty profile is unable to parse * * time duration values, such as 120m, * * for LTPA expiration. * **************************************************************** * RECOMMENDATION: * **************************************************************** Customer has used a well known String value shorthand to represent the LTPA timeout value, for example, 2h to represent 2 hours but the runtime appears to not recognize the value specified. This is because the runtime was coded to accept only Long values representing a time in minutes.
Problem conclusion
A change has been made to the metatype to allow users to specify time duration values, such as 2h, while defaulting any unitless values to minutes to match the existing behavior. The fix for this APAR is currently targeted for inclusion in fix pack 8.5.0.1. Please refer to the Recommended Updates page for delivery information: http://www.ibm.com/support/docview.wss?rs=180&uid=swg27004980
Temporary fix
Comments
APAR Information
APAR number
PM65535
Reported component name
LIBERTY PROFILE
Reported component ID
5724J0814
Reported release
850
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-05-25
Closed date
2012-09-14
Last modified date
2012-09-14
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
LIBERTY PROFILE
Fixed component ID
5724J0814
Applicable component levels
R850 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSEQTP","label":"WebSphere Application Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"850","Line of Business":{"code":"LOB45","label":"Automation"}}]