Fixes are available
APAR status
Closed as program error.
Error description
If the monitor-1.0 feature set is enabled and an application is being monitored for performance, the monitoring stops if the application is restarted.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IBM WebSphere Application * * Server Liberty Profile using the * * monitor-1.0 feature set. * **************************************************************** * PROBLEM DESCRIPTION: Servlet statistics for an application * * fail to update when application is * * restarted. * **************************************************************** * RECOMMENDATION: * **************************************************************** If performance monitoring is enabled, collecting RequestCount and ResponseTime data for an application, monitoring works while the application is running. When the user stops and starts the application, RequestCount/Responsetime do not change.
Problem conclusion
Monitoring data is reported using MXBeans. These MXBeans needed to be removed when the application is stopped. The fix for this APAR is currently targeted for inclusion in fix pack 8.5.0.1. Please refer to the Recommended Updates page for delivery information: http://www.ibm.com/support/docview.wss?rs=180&uid=swg27004980
Temporary fix
Comments
APAR Information
APAR number
PM69186
Reported component name
LIBERTY PROFILE
Reported component ID
5724J0814
Reported release
850
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-07-19
Closed date
2012-09-26
Last modified date
2012-09-26
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
LIBERTY PROFILE
Fixed component ID
5724J0814
Applicable component levels
R850 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSEQTP","label":"WebSphere Application Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"850","Line of Business":{"code":"LOB45","label":"Automation"}}]