Fixes are available
8.5.0.2: WebSphere Application Server V8.5 Fix Pack 2
8.0.0.6: WebSphere Application Server V8.0 Fix Pack 6
8.0.0.7: WebSphere Application Server V8.0 Fix Pack 7
8.0.0.8: WebSphere Application Server V8.0 Fix Pack 8
8.0.0.9: WebSphere Application Server V8.0 Fix Pack 9
8.0.0.10: WebSphere Application Server V8.0 Fix Pack 10
8.0.0.11: WebSphere Application Server V8.0 Fix Pack 11
8.0.0.12: WebSphere Application Server V8.0 Fix Pack 12
8.0.0.13: WebSphere Application Server V8.0 Fix Pack 13
8.0.0.14: WebSphere Application Server V8.0 Fix Pack 14
8.0.0.15: WebSphere Application Server V8.0 Fix Pack 15
APAR status
Closed as program error.
Error description
The Plug-in can not connect to an application server if it uses TLSv1.2 and is configured for strict SP800-131 compliance. The plug-in log will show serveriotimeout fired and have the following error message: ERROR: lib_stream: openStream: Failed in r_gsk_secure_soc_init: GSK_WOULD_BLOCK(gsk rc = 502) PARTNER CERTIFICATE DN=No Information Available, Serial=No Information Available
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: IBM WebSphere Application Server V8.0 and * * V8.5 web server plugin users * **************************************************************** * PROBLEM DESCRIPTION: If strict security is enabled on the * * application servers, connections may * * fail. * **************************************************************** * RECOMMENDATION: * **************************************************************** The security library in the web server plugin does not enable strict security by default. If strict security is enabled on the application server, connections will fail unless an insecure connection is also configured.
Problem conclusion
A property was added to allow plugin to enable security compatible with the application server strict server setting. To enable this property, set StrictSecurity=true on the webserver-><servername>->Plug-in properties->Custom Properties window. The fix for this APAR is currently targeted for inclusion in fix packs 8.0.0.6 and 8.5.0.2. Please refer to the Recommended Updates page for delivery information: http://www.ibm.com/support/docview.wss?rs=180&uid=swg27004980
Temporary fix
Comments
APAR Information
APAR number
PM74603
Reported component name
WEBS APP SERV N
Reported component ID
5724H8800
Reported release
800
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2012-10-09
Closed date
2012-11-08
Last modified date
2017-03-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WEBS APP SERV N
Fixed component ID
5724H8800
Applicable component levels
R800 PSY
UP
R850 PSY
UP
Document Information
Modified date:
29 October 2021