APAR status
Closed as program error.
Error description
The second number after decimal point is shown differently between Microsoft Internet Explorer and Mozilla Firefox. It seems that the result of rounding the value to two decimal places is different between the two browsers. They are not using JavaScript standard rounding (Number.toFixed()), but using the following Dojo round() function. i.e. dojo.number.round(0.95, 0) and dojox.math.round(0.95, 0) both return 2 instead of 1. The open source ticket is here: http://trac.dojotoolkit.org/ticket/16411.
Local fix
LOCAL FIX: None.
Problem summary
**************************************************************** * USERS AFFECTED: All users of IBM WebSphere Application * * Server Feature Pack for Web 2.0 and Mobile * * using Dojo's dojo.number.round or * * dojox.math.round. * **************************************************************** * PROBLEM DESCRIPTION: dojo.number.round and * * dojox.math.round return incorrect * * results on IE 6,7 and 8. * **************************************************************** * RECOMMENDATION: * **************************************************************** dojo.number.round and dojox.math.round return incorrect results on Microsoft Internet Explorer 6,7 or 8. Example: dojo.number.round(0.95, 0) returns 2 instead of 1. More details here: http://trac.dojotoolkit.org/ticket/16411.
Problem conclusion
The problem has been fixed and the correct value is now returned. The fix for this APAR is currently targeted for inclusion in fix pack 1.1.0.4. Please refer to the Recommended Updates page for delivery information: http://www.ibm.com/support/docview.wss?rs=180&uid=swg27004980
Temporary fix
Comments
APAR Information
APAR number
PM78423
Reported component name
WEBSPHERE APP S
Reported component ID
5724J0800
Reported release
850
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-12-04
Closed date
2013-01-16
Last modified date
2013-01-16
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WAS WEB 2.0 FEA
Fixed component ID
5724J0852
Applicable component levels
R700 PSY
UP
R800 PSY
UP
R850 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSEQTP","label":"WebSphere Application Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"850","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
10 February 2022